HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 HP BladeS - Page 13

Page 13 highlights

Example List the state of modules in an enclosure: vcsu -a healthcheck -i 192.168.0.100 -u Administrator -p password -vcu Administrator -vcp password packageinfo Extract the package information from the supplied package path and display the following information: • Digital Signature Validation (for Virtual Connect firmware version 2.30 and higher) • Package Version • Ethernet Firmware Version Timestamp • Ethernet Firmware Supported Hardware • FC Firmware Version • FC Firmware Supported Hardware • Release Notes (extract, not display) Item Syntax Parameter: FILE Description vcsu -a packageinfo -l Full path to the Virtual Connect package on the local computer or supported remote server Example Display package information from a file named VCpackage: vcsu -a packageinfo -l VCpackage report Display the current running firmware version on all modules in a specific target enclosure. Also display the VC-Enet and VC-FC firmware versions provided in the specified VC package file, and whether or not the module can be updated. In addition to displaying the module firmware version and status, the report command also displays details about the VC package contents. Because the package version details appear, you must provide a VC package file as part of the input at the command line. Item Syntax Parameters: IP USER PWD VCM USER Description vcsu -a report -i -u -p -vcu -vcp -l IPv4 address of the active OA in the enclosure* Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length is 1 character. Maximum length is 40 characters.** Password of the OA user. Minimum length is 3 characters. Maximum length is 40 characters.** Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual Connect domain. Minimum length is 1 character. Maximum length is 31 characters. Commands 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Commands 13
Example
List the state of modules in an enclosure:
vcsu -a healthcheck -i 192.168.0.100 -u Administrator -p password -vcu
Administrator -vcp password
packageinfo
Extract the package information from the supplied package path and display the following information:
Digital Signature Validation (for Virtual Connect firmware version 2.30 and higher)
Package Version
Ethernet Firmware Version Timestamp
Ethernet Firmware Supported Hardware
FC Firmware Version
FC Firmware Supported Hardware
Release Notes (extract, not display)
Item
Description
Syntax
vcsu -a packageinfo -l <FILE>
Parameter:
FILE
Full path to the Virtual Connect package on the local computer or supported remote server
Example
Display package information from a file named VCpackage:
vcsu -a packageinfo -l VCpackage
report
Display the current running firmware version on all modules in a specific target enclosure. Also display the
VC-Enet and VC-FC firmware versions provided in the specified VC package file, and whether or not the
module can be updated. In addition to displaying the module firmware version and status, the report
command also displays details about the VC package contents.
Because the package version details appear, you must provide a VC package file as part of the input at the
command line.
Item
Description
Syntax
vcsu -a report -i <IP> -u <USER> -p <PWD> -vcu <VCM USER> -vcp <VCM PASS>
-l <FILE>
Parameters:
IP
IPv4 address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length
is 1 character. Maximum length is 40 characters.**
PWD
Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**
VCM USER
Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual
Connect domain. Minimum length is 1 character. Maximum length is 31 characters.