HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 HP BladeS - Page 17

Page 17 highlights

Perform an update using a firmware image from an FTP server on the network: vcsu -a update -i 192.168.1.100 -u Administrator -p password -l ftp://user:[email protected]/vcfw-120.bin Perform an update of the same firmware version on a degraded module: vcsu -a update -i 192.168.1.100 -u Administrator -p password -l C:\images\vcfc-120.bin -f version,health version Display the current running firmware version on all modules in a specific target enclosure. Item Syntax Parameters: IP USER PWD VCM USER VCM PASS Description vcsu -a version -i -u -p -vcu -vcp IPv4 address of the active OA in the enclosure* Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length is 1 character. Maximum length is 40 characters.** Password of the OA user. Minimum length is 3 characters. Maximum length is 40 characters.** Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual Connect domain. Minimum length is 1 character. Maximum length is 31 characters. Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31 characters. *In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure. **In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across local and all remote enclosures in the Virtual Connect domain. Examples Display all modules and their current firmware versions: vcsu -a version -i 192.168.1.100 -u Administrator -p password -vcu Administrator -vcp password Commands 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Commands 17
Perform an update using a firmware image from an FTP server on the network:
vcsu –a update –i 192.168.1.100 –u Administrator –p password –l
ftp://user:[email protected]/vcfw-120.bin
Perform an update of the same firmware version on a degraded module:
vcsu -a update -i 192.168.1.100 -u Administrator -p password -l
C:\images\vcfc-120.bin -f version,health
version
Display the current running firmware version on all modules in a specific target enclosure.
Item
Description
Syntax
vcsu -a version -i <IP> -u <USER> -p <PWD> -vcu <VCM USER> -vcp <VCM
PASS>
Parameters:
IP
IPv4 address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length
is 1 character. Maximum length is 40 characters.**
PWD
Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**
VCM USER
Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual
Connect domain. Minimum length is 1 character. Maximum length is 31 characters.
VCM PASS
Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31
characters.
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.
Examples
Display all modules and their current firmware versions:
vcsu -a version -i 192.168.1.100 -u Administrator -p password -vcu
Administrator -vcp password