HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 HP BladeS - Page 16
Description, Examples, Update multiple modules in an enclosure imported into a VC domain
View all HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Item VCM PASS -q -oe -of -we -wf -cp Description Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31 characters. Optional. Specifies that the firmware update does not prompt for confirmation before updating, and uses the default answer for the confirmation (YES). Optional. Specifies VC-Enet module activation order. The following activation order methods are supported: • parallel-All modules are activated at the same time. • odd-even-(Default) The backup VC module is activated first. A force failover to the backup module occurs, and then the primary module is activated. The modules in odd bays are activated, and then modules in even bays are activated. • serial-The backup VC module is activated first. A force failover to the backup module occurs, and then the primary module is activated. A checkpoint is completed between the primary and standby module. Then the remaining modules are activated one at a time, starting with the lowest numbered bay. • manual-Modules are updated but not activated. Use the VC GUI or the OA GUI to activate (reboot) modules. Optional. Specifies VC-FC module activation order. The following activation order methods are supported: • parallel-All modules are activated at the same time. • odd-even-All modules in odd-numbered bays are activated first, and then modules in even-numbered bays are activated. • serial-(Default) Modules are activated one at a time, starting with the lowest numbered bay. • manual-Modules are updated but not activated. Use the OA GUI to activate (reboot) modules. Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting VC-Enet modules. This command is required for some MPIO/teaming software on the server blades in the enclosure. The default is 0, or no delay. HP recommends a minimum of 5 minutes. Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting VC-FC modules. This command is required for some MPIO/teaming software on the server blades in the enclosure. The default is 0, or no delay. HP recommends a minimum of 5 minutes. Optional. Password for the configuration backup file. Supported in VC firmware versions 3.00 and higher. The default is no password. *In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure. **In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across local and all remote enclosures in the Virtual Connect domain. Examples Update multiple modules in an enclosure imported into a VC domain: vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp vcPass -l C:\images\vcfw-120.bin Perform an update and specify an activation ordering method: vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp vcPass -l C:\images\vcfw-120.bin -oe serial -of parallel Perform an update using a firmware image from a web server address: vcsu -a update -i 192.168.1.100 -u Administrator -p password -l http://www.myserver.com/vcfw-120.bin Commands 16