HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 HP BladeS - Page 6
Command line syntax, Usage
View all HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
• IP addresses that are not accessible timeout within 20 seconds. IP addresses that have an active SSL enabled web server, but not an OA, fail immediately. • Only IPv4 addresses are supported in this release. • Prior to running VCSU, ensure that the maximum supported number of local user accounts for the Onboard Administrator has not been reached. For multi-enclosure domains, verify this information for each enclosure in the domain. Supported modules Module HP 1/10Gb Virtual Connect Ethernet Module HP 1/10Gb-F Virtual Connect Ethernet Module HP Virtual Connect Flex-10 10Gb Ethernet Module HP Virtual Connect FlexFabric 10Gb/24-port Module HP Virtual Connect Flex-10/10D Module HP 4Gb Virtual Connect Fibre Channel Module HP Virtual Connect 4Gb Fibre Channel Module HP Virtual Connect 8Gb 24-Port Fibre Channel Module HP Virtual Connect 8Gb 20-Port Fibre Channel Module Supported in VCSU 1.7.0 Yes* Yes* Yes Yes Yes Yes Yes Yes Yes * Supported only for updates to VC v3.60 or lower. This module is not supported for updates to VC v3.70 or higher. Command line syntax CLI input is case-insensitive except when otherwise noted. The general CLI syntax is as follows: vcsu -a Parameters are extensions that provide extra information required for the execution of a particular command. Whether or not a parameter is required depends on the specific action being executed. For example, the version command includes parameters for IP address, username, and password. The syntax is as follows: vcsu -a version -i -u -p NOTE: When entering a username from a Linux command shell with the domain\username format, use quotation marks around the username ("domain\username") so it is not expanded by the Linux shell. To display all modules and their current firmware version, enter the following: vcsu -a version -i 192.168.1.100 -u Administrator -p password Usage To install and run the HP BladeSystem c-Class Virtual Connect Support Utility: 1. Install the application on the client system by running the MSI file. 2. After the program is installed, click Start>Programs>Hewlett-Packard>Virtual Connect Support Utility to start a console. o To start the Virtual Connect Support Utility in interactive mode, enter vcsu. Introduction 6