HP Xw460c HP BladeSystem c7000 Enclosure Setup and Installation Guide
HP Xw460c - ProLiant - Blade Workstation Manual
View all HP Xw460c manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Xw460c manual content summary:
- HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 1
HP BladeSystem c7000 Enclosure Setup and Installation Guide Part Number 411272-006 March 2009 (Sixth Edition) - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 2
© Copyright 2006, 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 3
Power supply bay numbering ...14 Power supply LEDs...14 Device bay numbering ...15 HP BladeSystem Insight Display components 16 Enclosure rear components ...16 Fan bay numbering ...30 Installing a power supply...30 Installing blades ...31 Connecting locally to a server blade with video and USB - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 4
...77 Troubleshooting resources ...77 Important safety information...77 Symbols on equipment ...77 Warnings and cautions ...78 Insight Display errors ...79 Power errors ...80 Cooling errors...80 Location errors ...80 Configuration errors...80 Device failure errors...81 Technical support...82 Before - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 5
Grounding methods to prevent electrostatic discharge 96 Acronyms and abbreviations...97 Index...99 Contents 5 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 6
in any unused device bay Power supply blank A mandatory insert installed in any unused power supply bay Enclosure hot-plug power supply (quantity as ordered) The power supply for the enclosure Full-height device (quantity as The full-height server or storage blade ordered) Half-height device - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 7
instructions for blades, options and interconnects Installation checklist A checklist to guide you through installation of the enclosure and its components Rack requirements The enclosure is compatible with the following racks: • All HP 10000 and 10000G2 Series racks except the HP 10614 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 8
rear rack door to accommodate system cabling o Clearance-4.5 cm Rack-free environment requirements The HP BladeSystem c7000 Enclosure (referred to supporting the enclosure must be able to withstand this weight. • The enclosure should be supported on a surface that cannot support up to 217.7 kg (480 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 9
Observe local occupational health and safety requirements and guidelines for manual material handling. • Remove all installed enclosure components from support the weight of the enclosure. WARNING: Before installing an enclosure in the rack, be sure that all hot-plug power supplies, server blades, - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 10
or damage to the equipment, enter enclosures or perform service on system components only as instructed in the user documentation. WARNING: A risk of electric shock from high leakage current exists. Before connecting the AC supply to the power enclosures, be sure that the electrical outlets are - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 11
is always higher than the room temperature and is dependent on the configuration of equipment in the rack. Check the TMRA for each piece Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option. Planning - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 12
WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility. CAUTION: Protect the - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 13
intake slot (Do not block.) Power supply bay 1 Power supply bay 2 5 Power supply bay 3 6 Power supply bay 4 7 Insight Display 8 Power supply bay 5 9 Power supply bay 6 10 Air intake slot (Do not block.) *For more information, see "Device bay numbering (on page 15)." Component and LED - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 14
Power supply bay numbering Power supply LEDs Power LED 1 (green) Off On Off Fault LED 2 (amber) Off Off On Condition No AC power to the power supply Normal Power supply failure For power supply configuration information, see Installing a power supply ("Component installation" on page 30). - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 15
to provide network access for data transfer. Interconnects reside in bays located on the rear of the enclosure. Be sure to review device bay numbering to determine which external network connections on the interconnects are active. IMPORTANT: When looking at the rear of the enclosure, device - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 16
HP BladeSystem Insight Display components Item 1 2 3 4 5 6 Description Insight Display screen Left arrow button Right arrow button OK button Down arrow button Up arrow button Function Displays Main Menu error messages and instructions Moves the menu or navigation bar selection left one position - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 17
8 Onboard Administrator bay 2 Power supply exhaust vent (do not block) Fan bay 10 Fan bay 9 Fan bay 8 Fan bay 7 Fan bay 6 AC power connectors Onboard Administrator bay 1 Interconnect bay 7 Interconnect bay 5 Interconnect bay 3 Interconnect bay 1 Fan bay numbering Component and LED identification - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 18
Fan LED LED color Solid green Solid amber Flashing amber Fan status The fan is working. The fan has failed. See the Insight Display screen. Onboard Administrator components Item 1 2 3 Description Onboard Administrator bay 1 Onboard Administrator bay 2 (redundant, if used) Enclosure link-up port - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 19
, which provides Ethernet access to the Onboard Administrator and the iLO on each blade. Also supports interconnect modules with management processors configured to use the enclosure management network. Also supports GbE. UID LED Blue = UID on Active Onboard Administrator LED Indicates which - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 20
pinout. To access the KVM menu or Onboard Administrator CLI, connect a VGA monitor or rack KVM monitor for enclosure KVM. Interconnect bay numbering To support network connections for specific signals, install the interconnect module into the appropriate bay. Component and LED identification 20 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 21
Server blade signal NICs 1, 2, 3, and 4 (embedded) Mezzanine 1 Mezzanine 2 Mezzanine 3 Interconnect bay number 1, 2 3, 4 5, 6 and then 7, 8 7, 8 and then 5, 6 Interconnect bay label NOTE: For information on the location of LEDs and ports on individual interconnect modules, see the documentation - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 22
up the enclosure" on page 56) in the enclosure. 6. Connect the AC power cables and power up the enclosure ("Powering up the enclosure" on page 59). 7. Configure the enclosure ("Running the Insight Display installation steps" on page 64) using the Insight Display. Disassembling the enclosure Before - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 23
1. With the enclosure still on the pallet, remove all components from the front and rear of the enclosure. 2. Remove the rear cage: a. Loosen the thumbscrews and open the hinges completely. Installation 23 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 24
b. Use the handles to extend the rear cage until the release levers engage on both sides of the rear cage. c. Grasp the handholds below the release levers. d. Disengage the release levers on both sides of the rear cage. CAUTION: When removing and lifting the rear cage, always grasp the handholds as - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 25
stack an enclosure on top of another enclosure. • Never place equipment on top of an enclosure. • Never place an enclosure on a surface that cannot support up to 217.7 kg (480 lb). To set up the enclosure in a rack-free environment: 1. Select the location for the enclosure. For more information - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 26
the enclosure into the rack" on page 27). Measuring with the rack template The rack template ships with the rack rail kit and provides detailed instructions on where to position the enclosure rack rails and where to install the four cage or clip nuts. Each enclosure kit includes the rack rails - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 27
the enclosure with the rails while the other two people support the weight of the enclosure. To install the enclosure into the rack enclosure guiding fins with the guiding groove in the rack rails. IMPORTANT: Be sure that the guiding fins on the enclosure seat properly in the guiding groove - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 28
2. Push the handles down on each side of the enclosure, and slide the enclosure fully into the rack. 3. Tighten the thumbscrews to secure the enclosure to the rack. 4. Install the rear cage into the enclosure. ("Installing the rear cage into the enclosure" on page 29) 5. Repeat the procedure for the - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 29
cage into the enclosure 1. Open all hinges completely. 2. Position the rear cage at the rear of the enclosure, and align the rear cage guiding fins with the guiding groove in the rack rails. 3. Slide the rear cage fully into the enclosure. CAUTION: Do not touch or bump rear cage connector pins when - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 30
-phase power configuration, six power supplies are required. Single-phase configurations can have fewer than six power supplies. Install the power supplies based on the total number of supplies needed: • Two power supplies: Bays 1 and 4 • Three power supplies: Bays 1, 2, and 4 • Four power supplies - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 31
the status of the power supply. To calculate how many power supplies are needed, see the HP BladeSystem Power Sizer (http://www.hp.com/go/bladesystem/powercalculator). Installing blades The c7000 enclosure is divided into four quadrants by the vertical support metal work. Within each quadrant - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 32
be mounted on top of the storage blade. The lower tape or storage blade cannot be removed without first removing the upper half-height blade. Installing a full-height blade The HP BladeSystem c7000 Enclosure ships with four device bay shelves to support half-height devices. To install a full-height - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 33
1. Remove the blank. 2. Remove the three adjacent blanks. 3. Remove the device bay shelf ("Removing a device bay shelf" on page 35). 4. Remove the connector covers. Installation 33 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 34
. CAUTION: To prevent improper cooling and thermal damage, do not operate the blade or the enclosure unless all hard drive and device bays are populated with either a component or a blank. 7. Install blanks in any empty bays ("Creating a full- - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 35
Removing a device bay shelf 1. Remove the blank. 2. Slide the device bay shelf locking tab to the left to open it. Installation 35 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 36
3. Push the device bay shelf back until it stops, lift the right side slightly to disengage the two tabs from the divider wall, and then rotate the right edge downward (clockwise). 4. Lift the left side of the device bay shelf to disengage the three tabs from the divider wall, and then remove it - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 37
2. Fit the coupler plate into the slots on top of the blank, and slide the coupler plate back until it snaps into place. 3. Fit the slots on the bottom of the second blank on to the tabs on the coupler plate, and slide the second blank forward until it snaps in place. 4. Install the full-height - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 38
Remove the blank. 2. Install the device bay shelf, if applicable ("Installing a full-height blade" on page 32). 3. Install the blade in the empty bay. Installing a device bay shelf You must install the device bay shelf to support half-height devices. To install the device bay shelf: Installation 38 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 39
1. Remove the full-height blade, storage blade, or device bay blank. 2. Slide the device bay shelf locking tab to the left to unlock it. Installation 39 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 40
side of the shelf) are fully engaged before sliding the shelf forward to complete the installation. Failure to do so can cause damage to server blade connectors during installation. 4. Align the two tabs on the right edge of the device bay shelf with the openings, and slide the device bay shelf - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 41
keyboard • USB mouse • USB CD/DVD-ROM drive • USB diskette drive Numerous configurations are possible. This section offers two possible configurations. Accessing a server blade with local KVM For this configuration, a USB hub is not necessary. To connect additional devices, use a USB hub. CAUTION - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 42
The USB hub provides additional connections. Use the following configuration when configuring a blade or loading software updates and patches from a USB CD/DVD-ROM or a USB diskette drive. 1. Connect the HP c-Class Blade SUV cable to the blade. 2. Connect the video connector to a monitor. 3. Connect - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 43
or diskette drive Installing fans The HP BladeSystem c7000 Enclosure ships with four HP Active Cool 200 Fans and supports up to 10 fans. Install fans in even-numbered groups, based on the total number of blades installed in the enclosure. • Four fan configuration-Fan bays 4, 5, 9, and 10 are used - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 44
1. Turn the handle counterclockwise to the unlock position, and pull the fan or fan blank from the enclosure. 2. Slide the fan into the enclosure until it locks in place. NOTE: When installing a fan in the top row of fan bays, orient the fan so that the LED is in the lower right corner. When - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 45
c7000 Enclosure is shipped with one HP BladeSystem Onboard Administrator with KVM module installed and can support up to two Onboard Administrator modules. Install Onboard Administrator modules based on the total number ordered: • One Onboard Administrator module: Bay 1 • Two Onboard Administrator - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 46
into the Onboard Administrator tray, and close the handle. When the Onboard Administrator module is fully inserted, it locks into place. Attaching components to the HP c7000 Onboard Administrator with KVM For local access to the enclosure: 1. Connect a monitor (1) to the VGA connector (6) on the - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 47
KVM interface adapter (2) to the VGA connector (4) and the USB connector (3) on the HP Onboard Administrator with KVM. 2. Connect a CAT5 cable (1) to the KVM interface adapter (2) and an optional HP Console Switch (5). Installing interconnect modules There are eight single-wide interconnect bays in - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 48
NOTE: For more information on how and where to install mezzanine cards, see the serverspecific user guide. To install an interconnect module: 1. Remove the interconnect blank, if applicable. 2. If you are installing a double-wide interconnect module, remove the interconnect bay dividers ("Removing - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 49
"1x/2x" refers to the number of interconnect lanes per port provided by the controller. The more lanes provided per port, the higher the data transmission rate coming from that port. Mapping half-height blades The following table lists the available configurations for half-height devices installed - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 50
Connection Port number Connects to interconnect Comments bay/port Embedded NIC NIC 1 NIC 2 1/Port N 2/Port N One or two single-wide Ethernet interconnect modules Mezzanine slot 1-1x or 1x/ - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 51
Mapping full-height blades The following table lists the available configurations for full-height devices installed in device bay N (1-8). Connection Port number NIC NIC 1 NIC 2 NIC 3 NIC 4 Mezzanine slot 1-1x or 1x/2x port 1 2x cards 1x/2x port 2 1x/2x port 3 1x/2x port 4 Connects to - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 52
Port number Connects to Blades To support network connections for specific signals, install an interconnect module in the bay corresponding to the embedded NIC or mezzanine signals. Interconnect device mapping for double dense server blades The following table lists the available configurations - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 53
N 7/Port N 8/Port N Interconnect device mapping for AMC Telco I/O expansion blades The following table lists the available configurations for AMC Telco I/O expansion blades installed in device bay N (1-16). Connection Port number Connects to interconnect bay/port AMC Embedded (1) AMC Embedded - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 54
in mezzanine connector 3. The Onboard Administrator disables the device bay crosslinks when they cannot be used, such as when two server blades reside in adjacent device bays. Interconnect bay crosslinks Interconnect bay crosslinks are wired between adjacent interconnect bay pairs. Installation 54 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 55
You can enable these signals to provide module-to-module connections, such as Ethernet crosslink ports between matching switches, or Virtual Connect modules as stacking links. Onboard Administrator disables the interconnect bay crosslinks when they cannot be used, such as when two different modules - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 56
ships with the interconnect modules, or the HP ProLiant BladeSystem c-Class Site Planning Guide on the Documentation CD or the HP website (http://www.hp.com/go/bizsupport). 3. Connect to the AC or DC power source in your facility and power up the enclosure ("Powering up the enclosure" on page 59 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 57
Ethernet access to the Onboard Administrator and the iLO on each blade. Also supports interconnect modules with management processors configured to use the enclosure management network. Autonegotiates 1000/100/10 or can be configured to force 100Mb or 10Mb full duplex. USB USB 2.0 Type A connector - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 58
CAT5 patch cable. A Windows® PC automatically obtains an IP address. If no IP address is obtained, configure the PC Ethernet port for Service IP address found in the Enclosure Info screen in step 2. 4. Log into the Remote Onboard Administrator. See the HP BladeSystem Onboard Administrator User Guide - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 59
a single-phase AC configuration or a three-phase AC configuration. Single-phase AC configuration To cable the enclosure using a single-phase AC configuration: 1. Connect the AC power cables to the power connectors on the rear of the enclosure corresponding to the power supply that was populated on - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 60
cord retention bracket on the right side of the enclosure, ensure the power cord retention tabs are located on the left side of the snap clamps. 7. Place the power cord retention bracket under the power cords, and then align the power cords with the snap clamps. 8. Open the snap clamps, and then - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 61
be installed in either a 1U or a 0U configuration. See the installation instructions that came with the PDU for specific details on installing the PDU in the rack. NOTE: Rack-based single-phase PDUs cannot be used with a three-phase power configuration. NOTE: Total VA load of the attached enclosures - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 62
2. Connect the AC power cables to the installed PDU. 3. Power up the enclosure ("Powering up the enclosure" on page 59). Cabling and powering up the enclosure 62 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 63
takes to complete initialization depends on the number of blades configured in the enclosure. For example, a full enclosure of 16 blades might take 5 minutes to power up, while an enclosure with fewer blades might take less time. Server blades are powered up incrementally, starting from device bay - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 64
information on driver and firmware updates, see the HP website (http://www.hp.com/go/blades/). Running the Insight Display installation steps When the enclosure is powered up for the first time, the Insight Display launches an installation wizard to guide you through the configuration process. After - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 65
is blue because the enclosure UID is active when this screen appears. 1. Review each setting on the Enclosure Settings screen for accuracy. 2. To change any Power Mode-The default setting is AC Redundant. The following selections are valid: o AC Redundant o Power Supply Redundant HP BladeSystem - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 66
power supplies on standby automatically to increase overall enclosure power subsystem efficiency. o Disabled-All power supplies share the load; the power subsystem efficiency varies based is Not Set. HP recommends that you set a PIN to protect the enclosure configuration from unauthorized changes. - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 67
Settings = to one of the following values: o Yes-Copy the configured power settings, rack name, and LCD Lockout PIN (if set) from power settings. IMPORTANT: If your facility uses Static IP addressing for the Onboard Administrator modules, you must manually continuing. HP BladeSystem Insight Display 67 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 68
return to the Main Menu. Enclosure and blade hardware setup and configuration is complete. If errors are detected, the Insight Display screen illuminates amber, and the Health Summary screen appears. For more information on troubleshooting configuration and installation errors, see Insight Display - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 69
Port Info ("Blade and Port Info screen" on page 73) • Turn Enclosure UID On/Off ("Turn Enclosure UID On/Off screen" on page 74) • View User Note ("View User Note screen" on page 76) screen displays the total number of error conditions and the error locations. HP BladeSystem Insight Display 69 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 70
a component that is installed but powered off with no errors. The only option active on the navigation bar is Back to Main Menu. Select Back to Main Menu, and press the OK button to return to the main menu. If there is a configuration error between the blade and the interconnect module, the error - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 71
Select View Alert and press the OK button to display the errors. Select Details to view the details of the error. In the following example, the blade in bay 5 and the interconnect module in slot 3 have a configuration error. HP BladeSystem Insight Display 71 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 72
: • Redundancy mode setting • Limit AC input VA setting • Power Savings mode setting • Active and Standby OA IP addresses • Enclosure Service IP address • Current health status of the enclosure • Current enclosure ambient temperature • Current AC input power to the enclosure • Enclosure name HP - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 73
Info screen displays information about a specific blade. On the first screen, select the blade number, then press the OK button. Select Blade Info or Port Info, and press the OK button. To view information about the blade, select Blade Info and press the OK button. HP BladeSystem Insight Display 73 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 74
ports used by a specific blade, select Port Info and press the OK button. On the following full-height blade, there are four connected to particular port numbers on the interconnect modules. The following Port Info screen shows a configuration error. There is HP BladeSystem Insight Display 74 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 75
off the rear enclosure UID LED and changes the color of the Insight Display screen to the current condition ("Insight Display overview" on page 64). HP BladeSystem Insight Display 75 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 76
to display helpful information such as contact phone numbers or other important information. Change this screen using the remote Onboard Administrator user web interface. Both the background bitmap and the the remote Administrator on the web interface for LCD Chat. HP BladeSystem Insight Display 76 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 77
The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, error message interpretation, issue resolution, and software maintenance on ProLiant servers and server blades. This guide - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 78
power from the system. Warnings and cautions WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 79
the enclosure. To clear errors that occur after initial powerup and configuration, see the HP BladeSystem Onboard Administrator User Guide for information. The following types of errors can occur when installing and configuring the enclosure: • Power errors (on page 80) • Cooling errors (on page 80 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 80
bay (the Insight Display indicates the correct bay). o Remove the blade to correct the mezzanine card installation (the Insight Display will indicate the correct bay). For information on installing the mezzanine card, see the server-specific user guide on the Documentation CD. Troubleshooting 80 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 81
all components, including: • Server blades • Storage blades • Power supplies • Interconnect modules • Onboard Administrator modules • Fans • AC power inputs To correct a device failure error: 1. Use the arrow buttons to navigate to Fix This, and press OK. 2. Review and complete the corrective action - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 82
before you call HP: • Technical support registration number (if applicable) • Product serial number • Product model name and number • Product identification number • Applicable error messages • Add-on boards or hardware • Third-party hardware or software • Operating system type and revision - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 83
designated for your product. NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog. Based on availability and - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 84
le site Web HP (http://www.hp.com/go/ HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti. In base HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 85
Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSRErsatzteil geliefert werden, können Sie - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 86
cliente de HP, póngase HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP (of een HP Service product. OPMERKING: Sommige HP HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP a HP (ou fornecedores/parceiros de serviço da HP) concluir - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 87
entanto, se desejar que a HP as substitua, pode haver ou HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP HP para que um técnico o ajude por telefone. A HP especifica HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 88
Technical support 88 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 89
Technical support 89 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 90
product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product the interference potential of the device as well as additional operating instructions for the user. FCC rating label The FCC rating label on the device shows - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 91
in accordance with the instructions, may cause harmful interference Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 • 1281-514-3333 To identify this product, refer to the part, series, or model number found on the product. Modifications The FCC requires the user - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 92
is valid for EU non-harmonized Telecom products. *Notified body number (used only if applicable-refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany Disposal of waste equipment by users in private households in the European Union Regulatory - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 93
more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Japanese notice BSMI notice Korean notice Class A equipment Regulatory compliance notices 93 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 94
specified herein or in the laser product's installation guide may result in hazardous radiation exposure. user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP Authorized Service - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 95
collection system or return them to HP, an authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service Power cord statement for Japan Regulatory compliance notices 95 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 96
from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: • Avoid hand contact by transporting and storing products in static-safe containers. • Keep electrostatic - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 97
Acronyms and abbreviations CLI Command Line Interface CSA Canadian Standards Association CSR Customer Self Repair ESD electrostatic discharge I/O input/output IEC International Electrotechnical Commission iLO 2 Integrated Lights-Out 2 IP Internet Protocol LCD liquid crystal display LED light- - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 98
NIC network interface controller PDU power distribution unit RETMA Radio Electronics Television Manufactures Association (rack spacing) TMRA recommended ambient operating temperature UID unit identification UPS uninterruptible power system USB universal serial bus Acronyms and abbreviations 98 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 99
replacement notice 94 bay numbering, full-height device 15 bay numbering, half-height device 15 bay numbering, interconnect 53 bay numbering, power supply 14 bay to bay crosslinks 54 BL2x220c blades, mapping 52 Blade and Port Info screen 68, 73 BSMI notice 93 C cable configuration 56, 57, 58 cables - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 100
PDU 61 installing power supplies 30 installing rear cage 29 installing server blade 31 installing server blades 32, 38 installing the rails 25, 26 interconnect bay crosslinks 54 interconnect bay dividers, installing 47, 55 interconnect bay dividers, removing 47, 55 interconnect bay numbering 53 - HP Xw460c | HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 101
server blade 52 port types 48 power cables 59 power configurations 59 power cord 78, 95 power distribution unit (PDU) 12, 61 power errors 80 power requirements 11 power supplies 30 power supply bay numbering 14 power supply LEDs 14 powering up the enclosure 56, 59 preparation procedures 6 problem
HP BladeSystem c7000 Enclosure
Setup and Installation Guide
Part Number 411272-006
March 2009 (Sixth Edition)