HP Xw460c HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 74

Turn Enclosure UID On/Off screen

Page 74 highlights

To view the ports used by a specific blade, select Port Info and press the OK button. On the following full-height blade, there are four embedded NICs. There are two interconnect modules located in interconnect bays 1 and 5, shown with bright green highlights. The other interconnect bays are empty. The four embedded NICs are connected to particular port numbers on the interconnect modules. The following Port Info screen shows a configuration error. There is a mismatch between the mezzanine card and interconnect module. Interconnect bay 3 contains a Fibre Channel interconnect module. Mezzanine 1 on the blade is a gigabit Ethernet which does not match the technology of the interconnect module. Therefore an error displays. Turn Enclosure UID On/Off screen The main menu option displays "Turn Enclosure UID Off" when the enclosure UID is active, and displays "Turn Enclosure UID on" when the enclosure UID is off. HP BladeSystem Insight Display 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

HP BladeSystem Insight Display
74
To view the ports used by a specific blade, select
Port Info
and press the OK button.
On the following full-height blade, there are four embedded NICs. There are two interconnect modules
located in interconnect bays 1 and 5, shown with bright green highlights. The other interconnect bays are
empty. The four embedded NICs are connected to particular port numbers on the interconnect modules.
The following Port Info screen shows a configuration error. There is a mismatch between the mezzanine
card and interconnect module. Interconnect bay 3 contains a Fibre Channel interconnect module.
Mezzanine 1 on the blade is a gigabit Ethernet which does not match the technology of the interconnect
module. Therefore an error displays.
Turn Enclosure UID On/Off screen
The main menu option displays "Turn Enclosure UID Off" when the enclosure UID is active, and displays
"Turn Enclosure UID on" when the enclosure UID is off.