HP Xw460c HP BladeSystem c7000 Enclosure Setup and Installation Guide - Page 67
The Check: Installation and Cables screen appears., Accept All, Push Settings, Accept
View all HP Xw460c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
5. Navigate to the Accept All button at the bottom of the Enclosure Settings screen, and press the OK button to accept all the settings and continue. 6. In the Check: Linked Enclosures screen, the message Linked enclosures detected appears if the Onboard Administrator module detects other enclosures. Use the up and down arrow buttons to change Push Settings = to one of the following values: o Yes-Copy the configured power settings, rack name, and LCD Lockout PIN (if set) from the Enclosure Settings screen to the detected enclosures. o No-Continue configuring the current enclosure only. The Insight Display installation wizard must be run on each of the other detected enclosures. Select this option if each enclosure requires different power settings. IMPORTANT: If your facility uses Static IP addressing for the Onboard Administrator modules, you must manually enter those IP addresses into the Insight Display for each Insight Display separately. You can enter those Onboard Administrator module IP addresses before you send the settings to adjacent enclosures. You can return to the Enclosure Settings menu after the Installation Wizard completes to change the Onboard Administrator module IP addresses, if necessary. 7. Navigate the cursor to Accept, and press the OK button. The Check: Installation and Cables screen appears. 8. Verify all components are installed and cabled before continuing. HP BladeSystem Insight Display 67