HP rp5400 User Guide - HP rp5400 Family of Servers - Page 106
Table 6-2, Chassis Log Error to FRU Decoder Continued, Chassis Log Field Values and Descriptions
View all HP rp5400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Troubleshooting Chassis Code to FRU Decode Table 6-2 Chassis Log Error to FRU Decoder (Continued) Chassis Log Field Values and Descriptions from Log Entry Source 3 - PDH 4 - Power 4 - Power 4 - Power 6 - Platform 6 - Platform 6 - Platform 7 - Memory 7 - Memory 8 - I/O Source Detail Source ID Not Applicable N/A (N/A) 1 - AC Mains N/A 3 - Low Voltage DC Power CPU Support Module # 4 - High Voltage Power DC Power Supply # 3 - Cabinet Fan Fan # 6 - Service N/A Processor 7 - Power N/A Monitor 1 - Controller N/A 4 - SIMM or N/A DIMM 6 - Disk N/A Problem Detail FRU Action to Take N/A System Replace the System Board Board. 9 - Power Off AC Power Check that AC is being supplied to all power supplies. N/A CPU Replace the Support Processor Support Module Module (on the System Board) referenced in the Source ID. N/A Power Replace the Power Supply Supply (in the front of the system behind the bezel) referenced in the Source ID. N/A Fan Replace the Fan referenced in the Source ID. N/A Core I/O The Service Processor is on the GSP I/O board. Replace the GSP N/A Power Replace Platform Monitor Monitor card. N/A System Replace the System Board Board. N/A Memory Isolate to failing DIMM DIMM using BCH (IN, ME) and ODE memory diagnostic. Various Values Disk Subsyste m Use BCH commands and ODE diagnostics to check disk subsystem. 92 Chapter 6