Honeywell 3800ISR050E User Manual - Page 55
Output Sequence Editor, Require Output Sequence, Discard, Required, On/Not Required
View all Honeywell 3800ISR050E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Other Programming Selections •Discard This exits without saving any Output Sequence changes. Output Sequence Editor Enter Sequence Default Sequence Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it's On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence, but if it cannot, the scanner transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Required On/Not Required * Off Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. 3800i/3800r User's Guide 3 - 11