Installation Instructions A3. CHECK BLOWER MOTOR ORIENTATION The blower fan blade opening should be facing the front of the microwave. You will have to remove the top cover plate to check the fan blade orientation. If the fan opening is already facing the front of the microwave, skip to step A5. Otherwise, continue to Step A4 to adjust the fan motor orientation. A4. ADAPTING BLOWER FOR RECIRCULATION NOTE: The exhaust adaptor with damper is not needed for recirculating models. You may want to save them for possible future use. 1 Remove and save screws that hold blower plate to the oven. Blower Plate Screws Blower Plate Back of Oven Cover Plate 2 Slide the blower plate from under its retaining flange and lift it off. Remove the cover plate installed on the back. Remove and save screws that hold blower unit to the oven. Retaining Flange Blower Plate Blower Motor Screws Cover Plate 3 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. 4 Roll the blower unit 90° so that fan blade openings are facing toward the front of the oven. BEFORE: Fan Blade Openings Facing Up Roll AFTER: Fan Blade Openings Facing Forward 31-7000091 Rev. 2 13