Husqvarna EZ4824 Owners Manual - Page 39
Air Filter, Briggs & Stratton Engine
View all Husqvarna EZ4824 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
maintenance Air Filter Briggs & Stratton Engine 1. Loosen screws and remove air filter cover. 2. Remove the filter cartridge by pulling upwards along the outside edge. WARNING! The engine and the exhaust system become very hot during operation. Risk for burns if touched. Allow engine and exhaust system to cool at least two (2) minutes. Loosen cover screws 3. Remove the foam filter (precleaner). Clean the foam filter with mild detergent and water. Squeeze dry in a clean cloth. Do not oil the foam sleeve. 4. Tap the paper filter against a fixed surface to remove dust. If the paper filter is still dirty, it must be replaced. 5. Wipe clean the inside of air filter housing. 6. Refit the foam filter (pre filter). IMPORTANT INFORMATION Do not use compressed air to clean the air filter. Do not wash the paper filter. Do not oil the paper filter. 7. Mount the filter in the air filter housing. 8. Replace the cover over the air filter housing and secure with screws. Remove filter IMPORTANT INFORMATION Operating the engine with loose or damaged air cleaner components could allow unfiltered air into the engine causing premature wear and failure. Reinstall filter 8009-406 8019-014 8019-015 Husqvarna-39