Husqvarna EZ4824 Owners Manual - Page 56

Purging Procedures, If injured by escaping fluid

Page 56 highlights

LUBRICATION Purging Procedures Due to the effects air has on efficiency in hydrostatic drive applications, it is critical to purge the system. These purge procedures should be implemented any time a hydrostatic system has been opened to facilitate maintenance or any additional oil has been added to the system. Resulting symptoms in hydrostatic systems may be: 1. Noisy operation. 2. Lack of power or drive after short term operation. 3. High operation temperature and excessive expansion of oil. 4. Shortened component life. Before starting, make sure the pump is at the proper oil level. If not, fill to the specifications outlined prior. The following procedures are best performed with the vehicle drive wheels off the ground, then repeated under normal operating conditions. 1. Disengage the brake if activated. 2. With the bypass valve open and the engine running at fast idle, slowly move the steering control in both forward and reverse directions (5 or 6 times). As air is purged from the unit, the oil level will drop. 3. With the bypass valve closed and the engine running, slowly move the steering control in both forward and reverse directions (5 to 6 times). Check the oil level and add oil as required after stopping the engine. 4. It may be necessary to repeat Steps 2 and 3 until all the air is completely purged from the system. When the transaxle operates at normal noise levels and moves smoothly forward and reverse at normal speeds, the transaxle is considered purged. 5. After the vehicle has been used two times, the oil level should be checked while the oil is cold and adjusted accordingly. WARNING! Escaping hydraulic oil under pressure can have sufficient force to penetrate the skin, causing serious injury. If injured by escaping fluid, see a doctor at once. Serious infection or reaction can develop if proper medical treatment is not administered immediately. Disengage the parking brake 8058-020 56-Husqvarna

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

LUBRICATION
56
-Husqvarna
Purging Procedures
Due to the effects air has on efficiency in hydrostatic
drive applications, it is critical to purge the system.
These purge procedures should be implemented
any time a hydrostatic system has been opened to
facilitate maintenance or any additional oil has been
added to the system.
Resulting symptoms in hydrostatic systems may be:
Noisy operation.
1.
Lack of power or drive after short term operation.
2.
High operation temperature and excessive
3.
expansion of oil.
Shortened component life.
4.
Before starting, make sure the pump is at the proper
oil level. If not, fill to the specifications outlined prior.
The following procedures are best performed with the
vehicle drive wheels off the ground, then repeated
under normal operating conditions.
Disengage the brake if activated.
1.
With the bypass valve open and the engine
2.
running at fast idle, slowly move the steering
control in both forward and reverse directions (5 or
6 times). As air is purged from the unit, the oil level
will drop.
With the bypass valve closed and the engine
3.
running, slowly move the steering control in both
forward and reverse directions (5 to 6 times).
Check the oil level and add oil as required after
stopping the engine.
It may be necessary to repeat Steps 2 and 3 until
4.
all the air is completely purged from the system.
When the transaxle operates at normal noise
levels and moves smoothly forward and reverse
at normal speeds, the transaxle is considered
purged.
After the vehicle has been used two times, the oil
5.
level should be checked while the oil is cold and
adjusted accordingly.
8058-020
Disengage the parking brake
WARNING!
Escaping hydraulic oil under
pressure can have sufficient force to
penetrate the skin, causing serious
injury.
If injured by escaping fluid,
see a doctor at once. Serious
infection or reaction can develop
if proper medical treatment is not
administered immediately.