    Rack Console Switch Installation and User's Guide For 17353LX and 17354LX
  • IBM 17353LX | User Guide - Page 2
  • IBM 17353LX | User Guide - Page 3
    Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 4
  • IBM 17353LX | User Guide - Page 5
  • IBM 17353LX | User Guide - Page 6
    statement appear in the IBM Safety Information book under statement 1. Be sure to read all caution and danger statements in this documentation before performing the instructions. Read any additional safety information that comes with your server or optional device before you install the device.
  • IBM 17353LX | User Guide - Page 7
  • IBM 17353LX | User Guide - Page 8
  • IBM 17353LX | User Guide - Page 9
    IBM Conversion Options and Console Switch Cables 2 OSCAR Graphical User Interface ...3 Security ...3 Video ...3 Plug and Play...4 Firmware Upgrades...4 Tiering Expansion...4 Chapter 2: Installation ...7 Safety Precautions ...8 Mounting the Rack Console Switch 10 Installing the switch vertically
  • IBM 17353LX | User Guide - Page 10
    viii IBM Rack Console Switch Installation and User's Guide Configuring the display behavior 34 Configuring the status flag ...35 Configuring rack console switch security 37 Accessing Options and Buttons on the Commands Window 40 Using the Version Window ...41 Resetting the Keyboard and Mouse 44
  • IBM 17353LX | User Guide - Page 11
    servers that have USB-based KVM ports 3 Figure 1.3: Example rack console switch configuration (for 2 x 16 5 Figure 2.1: Rack console switch vertical installation 11 Figure 2.2: Rack console switch horizontal installation 12 Figure 2.3: Example rack console switch configuration (2 x 16 model 13
  • IBM 17353LX | User Guide - Page 12
    x IBM Rack Console Switch Installation and User's Guide Figure 3.21: Diagnostics window...47 Figure 3.22: Diag Warning window 48 Figure 3.23: Broadcast window ...49 Figure 3.24: Broadcast enable window 50 Figure 3.25: Switch window ...51 Figure 3.26: Keyboard window ...52 Figure 3.27: Keyboard
  • IBM 17353LX | User Guide - Page 13
    Rack console switch models, ports, users, maximum tiered and daisy-chained servers.. 2 Table 1.2: Console switch cable resolution and refresh rate 3 Table 2.1: Tiering of rack console switches 16 Table 2.2: Earlier model switches with support for one-level tiering 18 Table 2.3: IBM LCM2 support
  • IBM 17353LX | User Guide - Page 14
    xii IBM Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 15
    can optionally configure users to restrict access to specified servers. The firmware is upgradable through a configuration port. The firmware provides support for the following types of intelligent connectors: • IBM Conversion Options (KCO and UCO) • IBM Console Switch Cables (PS/2 and USB) Before
  • IBM 17353LX | User Guide - Page 16
    2 IBM Rack Console Switch Installation and User's Guide Models and Features An IBM 1 x 8 Rack Console Switch supports access by a single local user. An IBM 2 x 16 Rack Console Switch supports simultaneous access by two local users. The following table summarizes the features provided by the two
  • IBM 17353LX | User Guide - Page 17
    connect a server that has USB-based KVM ports. UCO USB console switch cable Figure 1.2: Options for connecting servers that have USB-based KVM ports OSCAR Graphical User Interface The OSCAR interface provides intuitive menus to configure the rack console switch and select servers. Administrators
  • IBM 17353LX | User Guide - Page 18
    4 IBM Rack Console Switch Installation and User's Guide Table 1.2: Console switch cable resolution and refresh rate (Continued) Maximum Resolution 800 x 600 800 x 600 800 x 600 Refresh Rate 56 Hz 60 Hz 72 Hz Refresh Rate VESA VESA
  • IBM 17353LX | User Guide - Page 19
    Rack console switch (tiered) Earlier-model switch (tiered) Chapter 1: Product Overview 5 Rack of servers Console switch cable or CO Critical server Local user B Rack console switch (main) Local user A Figure 1.3: Example rack console switch configuration (for 2 x 16)
  • IBM 17353LX | User Guide - Page 20
    6 IBM Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 21
    CD • Quick Installation Guide • 1U filler panel Additional items needed: • One Phillips screwdriver • For each server to be attached or daisy chained: • One IBM Conversion Option (KCO or UCO) and one CAT 5 cable -or• One IBM 3M Console Switch Cable (PS/2 or USB) • For each rack console switch to be
  • IBM 17353LX | User Guide - Page 22
    8 IBM Rack Console Switch Installation and User's Guide Safety Precautions Use the following safety guidelines to help ensure your own personal safety and to help protect the system and working environment from potential damage.
  • IBM 17353LX | User Guide - Page 23
    on the rack console switch components, and never operate the rack console switch in a wet environment. If the rack console switch gets wet, see the appropriate section in the troubleshooting guide or contact the trained service provider. • Use the rack console switch only with approved equipment
  • IBM 17353LX | User Guide - Page 24
    10 IBM Rack Console Switch Installation and User's Guide • Operate the rack console switch only from the type of external power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult the service provider or local power company. • Be sure
  • IBM 17353LX | User Guide - Page 25
    to the rack documentation for information about relocating side braces if they are not already spaced for this installation. Figure 2.1: Rack console switch vertical installation Installing the switch horizontally in the 1 U rack mounting space NOTE: The filler panel must be placed in front of the
  • IBM 17353LX | User Guide - Page 26
    12 IBM Rack Console Switch Installation and User's Guide through the slots in the mounting bracket and the holes in the mounting rail, then into the cage nuts or clip nuts. Figure 2.2: Rack console switch horizontal installation Configuring the Rack Console Switch Plug the supplied power cord into
  • IBM 17353LX | User Guide - Page 27
    Chapter 2: Installation 13 Local User B Configuration port (for updating firmware) ACI port Rack console switch ACI port ACI port ARI ports Local user A Local user A Servers 2-16 Servers 2-16 Local User A Server 1 Figure 2.3: Example rack console switch configuration (2 x 16 model)
  • IBM 17353LX | User Guide - Page 28
    IBM Rack Console Switch Installation and User's Guide b. Connect the RJ-45 end of a CAT 5 cable to the first RJ-45 connector on the unattached end of the CO. c. If you are not daisy-chaining other servers off this server, attach a terminator to the second RJ-45 connector on the console switch cable
  • IBM 17353LX | User Guide - Page 29
    Chapter 2: Installation 15 This procedure assumes that you are using one or more KCOs to daisy chain two or more servers. One server is already connected to an ARI port on the rack console switch using a KCO. 1. Make sure that each server you want to connect to the switch is turned off. 2. Connect a
  • IBM 17353LX | User Guide - Page 30
    16 IBM Rack Console Switch Installation and User's Guide 3. On a UCO connected to a server that is either already connected to an ARI port or daisychained, attach one end of a CAT 5 cable to the second RJ-45 connector. 4. Attach the other end of the CAT 5 cable to the first RJ-45 connector on a UCO
  • IBM 17353LX | User Guide - Page 31
    user B (2 x 16 only) Chapter 2: Installation 17 Rack console switch ARI ports 15 primary servers Tiered (secondary) rack console switch ACI port 16 secondary servers Figure 2.6: Rack console switch configuration with a tiered switch (2 x 16 model shown) Tiering multiple rack console switches
  • IBM 17353LX | User Guide - Page 32
    18 IBM Rack Console Switch Installation and User's Guide 3. Attach one end of a CAT 5 cable to the RJ-45 connector (ACI port) on local user A on the tiered rack console switch. 4. Attach the other end of a CAT 5 cable to one of the 16 RJ-45 (ARI) ports on the main rack console switch. NOTE: The
  • IBM 17353LX | User Guide - Page 33
    Installation 19 The IBM Local 2x8 Console Manager (LCM2) model supports two levels of tiering as shown in the following table. Table 2.3: IBM LCM2 support for two-level tiering Primary Switch Secondary Switch IBM LCM2 IBM LCM2 IBM LCM2 IBM LCM2 Tertiary Switch IBM 1 x 8 Console Switch/ IBM
  • IBM 17353LX | User Guide - Page 34
    20 IBM Rack Console Switch Installation and User's Guide Figure 2.7: IBM 2 x 16 Rack Console Switch example configuration with an earlier-model switch
  • IBM 17353LX | User Guide - Page 35
    with that switch. 6. Power cycle the earlier-model switch to enable its local port to recognize the switch cable or CO. 7. Repeat steps 2 to 6 for all earlier-model switches you want to attach. Configuring Access to the Rack Console Switch System See Chapter 3 for instructions about server and user
  • IBM 17353LX | User Guide - Page 36
    22 IBM Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 37
    sequences may be configured as described in "Configuring the hot key sequence for launching the OSCAR interface or the login window" on page 34. Accessing the rack console switch 1. Press the Print Screen key on the keyboard of a local user station attached to the rack console switch. If logging in
  • IBM 17353LX | User Guide - Page 38
    24 IBM Rack Console Switch Installation and User's Guide 2. If logging in is required, the Login window opens. Figure 3.1: Login window 3. To log in as an administrator, enter Admin in the Username field and enter the configured password in the Password field. 4. To log in as a regular user, do the
  • IBM 17353LX | User Guide - Page 39
    Interface 25 Figure 3.2: Example Main window with server names configured Each connected server, tiered switch, and daisy-chained CO has a separate entry in and eID are stored in the memory of the CO or console switch cable connected to the server and are retained even if the connector is removed
  • IBM 17353LX | User Guide - Page 40
    26 IBM Rack Console Switch Installation and User's Guide The status of the servers in the system is indicated in the right columns of the Main window. The following table describes the status symbols. Table 3.2: OSCAR interface status symbols Symbol Description The CO or console switch cable is
  • IBM 17353LX | User Guide - Page 41
    configuration and on whether a previous user is still logged in, either the server's login screen or login prompt or the server's console needed, see "Accessing the rack console switch" on page 23. 2. Make sure a screen delay time is set. If needed, see "Configuring a screen delay time" on page
  • IBM 17353LX | User Guide - Page 42
    28 IBM Rack Console Switch Installation and User's Guide Table 3.3: OSCAR interface navigation basics (Continued) Action Result F1 Opens the Help window for the current window. Closes the current window without saving changes and
  • IBM 17353LX | User Guide - Page 43
    anyone with physical access to a local user station connected to the rack console switch can perform configuration from the Setup window within the OSCAR interface. Figure 3.3: Setup window If the Admin account is configured, a regular user's access to configuration windows from the Setup window is
  • IBM 17353LX | User Guide - Page 44
    30 IBM Rack Console Switch Installation and User's Guide As shown in Figure 3.4, buttons on the Setup window for regular users give server is connected by means of a console switch cable, the names PS/2 and USB are shown. Switch Enable share mode. Choose the switch mode and the share mode time-out.
  • IBM 17353LX | User Guide - Page 45
    assigned to a server is stored in the console switch cable or CO, so even if you move the cable or CO to another ARI port, the name and configuration of the server is still recognized by the switch. NOTE: If a server is turned off, its CO or console switch cable does not appear in the Names list
  • IBM 17353LX | User Guide - Page 46
    32 IBM Rack Console Switch Installation and User's Guide Figure 3.6: Name modify window 4. Type a name in the New Name field up NOTE: The Modify button is available only if a configurable switch is selected. Defining the number of ports on a tiered switch 1. Access the Setup window. If needed, see "
  • IBM 17353LX | User Guide - Page 47
    . 4. Click Modify. The Device Modify window opens. Figure 3.8: Device modify window 5. Choose the number of ports supported by the tiered switch and click OK. If the number of ports on the tiered switch is not listed, click Other and type a port number between 4 and 24. 6. Click OK. 7. Repeat steps
  • IBM 17353LX | User Guide - Page 48
    34 IBM Rack Console Switch Installation and User's Guide Configuring the display behavior Use the Menu window to do the following tasks: • Configure the key sequence that launches the OSCAR interface. • Configure a Screen Delay Time to set a number of seconds to delay the display of the OSCAR
  • IBM 17353LX | User Guide - Page 49
    NOTE: Setting a Screen Delay Time enables you to complete a soft switch without the OSCAR interface appearing. To perform a soft switch, see "Soft switching using a hot key sequence" on page 27. Configuring the status flag When a user is connected to a server, a status flag displays on the desktop
  • IBM 17353LX | User Guide - Page 50
    36 IBM Rack Console Switch Installation and User's Guide Figure 3.10: Flag window Determining the display of to show the flag all the time or select Timed to display the flag for only five seconds after switching. 4. Select a flag color in the Display Color area. 5. In the Display Mode area, select
  • IBM 17353LX | User Guide - Page 51
    Configuring rack console switch security The Security window enables you to configure the following types of security protections: • You can configure for all users when restricted access is not configured. When access is restricted, only the Admin user sees this window, and regular users see only
  • IBM 17353LX | User Guide - Page 52
    38 IBM Rack Console Switch Installation and User's Guide Figure 3.13: Security window (user) Setting or changing the current user's password support. See "Appendix C: Technical Support" for contact information. If you are a regular user and you forget your password, contact your rack console switch
  • IBM 17353LX | User Guide - Page 53
    the window without saving changes. NOTE: After the specified Inactivity Time, the screen saver turns on. Activation of the screen saver disconnects the current user from a server. The status flag displays Free. Exiting the screen saver mode 1. Press any key or move the mouse. 2. If logging in is
  • IBM 17353LX | User Guide - Page 54
    40 IBM Rack Console Switch Installation and User's Guide Accessing Options and Buttons on the Commands Window The functions that are available on the Commands window vary depending on whether restricted access is configured as described in Chapter 4. Figure 3.14 shows the Commands window that
  • IBM 17353LX | User Guide - Page 55
    41 2. Click Commands. The Commands window opens. Using the Version Window Use the Version window to view the version numbers of the rack console switch hardware and firmware. In this window, you can also click the Target button to access additional windows, which allow you to view and upgrade the
  • IBM 17353LX | User Guide - Page 56
    42 IBM Rack Console Switch Installation and User's Guide Figure 3.17: Target Selection window 4. Select the name of a server and click the Version button. The Target Version window opens and displays the hardware and firmware versions of the connector used to attach the selected server. Figure 3.18:
  • IBM 17353LX | User Guide - Page 57
    the Target Selection window. Resetting a console switch cable NOTE: If a tiered switch is not recognized, you can use the Reset button to reset a PS/2 console switch cable attached to the tiered switch. (Be sure that the PS/2 console switch cable is connected to a tiered switch and not to a server
  • IBM 17353LX | User Guide - Page 58
    IBM Rack Console Switch Installation and User's Guide 3. Click Target. The Target Selection window opens. 4. Select the name of the server that is connected to a tiered server with the console switch cable message window. Configuring Scanning In scan mode, the rack console switch automatically scans
  • IBM 17353LX | User Guide - Page 59
    Chapter 3: Using the OSCAR Interface 45 Figure 3.20: Scan window 2. Do one of the following to select a server: • Click the check box next to a server. -or• Double-click on the server name or port. -or• Press Alt and the number of the server you want to scan. 3. In the Scan Time field, type the
  • IBM 17353LX | User Guide - Page 60
    46 IBM Rack Console Switch Installation and User's Guide Setting the scan duration 1. Access the Setup->Scan window as described in the two previous procedures. 2. Type a value in the Scan Time field. The duration
  • IBM 17353LX | User Guide - Page 61
    board RAM Validates the current firmware images stored in the system's Flash Verifies the switch matrix controller is accessible and have been connected successfully in the past and are powered down Indicates the number of targets that have message opens to indicate that all users are disconnected.
  • IBM 17353LX | User Guide - Page 62
    48 IBM Rack Console Switch Installation and User's Guide Figure 3.22: Diag Warning window 3. Click OK to begin diagnostics. -orClick X or press Esc to exit the window without running a diagnostic test. All users are disconnected during diagnostics, and the Diagnostics window displays. 4. As each
  • IBM 17353LX | User Guide - Page 63
    identically. Specifically, the Caps Lock and Num Lock modes must be the same on all keyboards. While the rack console switch attempts to broadcasting mouse movements to multiple systems can have unpredictable results. Configuring broadcasting to selected servers 1. Access the Broadcast window. If
  • IBM 17353LX | User Guide - Page 64
    50 IBM Rack Console Switch Installation and User's Guide Figure 3.24: Broadcast enable window 7. Click OK to enable broadcasting. 8. Type the information and perform the mouse movements you want to broadcast from the user station. NOTE: Access by a second local user is disabled when broadcast mode
  • IBM 17353LX | User Guide - Page 65
    is Used Use the Keyboard window to set the keyboard language when a non-English keyboard is connected to a local user station and servers with USB ports are connected to the switch. Setting the keyboard language 1. Access the Setup window. If needed, see "Accessing the Setup window" on page 30
  • IBM 17353LX | User Guide - Page 66
    52 IBM Rack Console Switch Installation and User's Guide Figure 3.26: Keyboard window 3. Select the checkbox language. Setting the Language for the OSCAR interface You can use the Language window to configure the language used by the OSCAR interface. Selecting a language 1. Access the Setup window.
  • IBM 17353LX | User Guide - Page 67
    Chapter 3: Using the OSCAR Interface 53 2. Click Language. The Language window displays. Figure 3.28: Language window 3. Select the desired language. 4. Click OK to change the OSCAR interface language and return to the Setup window. -orClick X or press Esc to exit without changing the keyboard
  • IBM 17353LX | User Guide - Page 68
    54 IBM Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 69
    Access By default, anyone with physical access to a local user station connected to the rack console switch can access all functions of the OSCAR interface and access all attached servers. You can use the OSCAR interface to configure restricted access as described in this section. After restricted
  • IBM 17353LX | User Guide - Page 70
    56 IBM Rack Console Switch Installation and User's Guide Figure 4.1: User Setup window Configuring users with the User Setup window The User Setup window allows the administrator to edit, access, or delete a user account. The window is only accessible if the Enable User Account checkbox is enabled
  • IBM 17353LX | User Guide - Page 71
    orClick X or press Esc to exit the window without saving changes. 5. To configure server access for the selected user, click Access. The User Access window opens. Figure 4.3: User Access window a. To assign all servers to the user, click the Check All button. b. To assign an individual server to the
  • IBM 17353LX | User Guide - Page 72
    58 IBM Rack Console Switch Installation and User's Guide c. To clear access to all servers for the user (instead of deleting the account) click the Clear All button. d. Click OK to save the changes. -orClick X or press Esc to exit the window without saving changes. 6. To restore the selected user
  • IBM 17353LX | User Guide - Page 73
    rack console switch firmware 1. Connect a standard serial cable to a COM port on the computer and to the configuration port on the back panel of the rack console switch. Make a note of which COM port you use, and then turn on the switch. 2. On the connected computer, go to http://www.ibm.com/support
  • IBM 17353LX | User Guide - Page 74
    60 IBM Rack Console Switch Installation and User's Guide 8. Once the firmware is updated, an Update Complete message displays. Click the Close button to exit the window. 9. The switch automatically reboots after the upgrade is completed. Troubleshooting possible error conditions If the firmware does
  • IBM 17353LX | User Guide - Page 75
    Appendices 61 NOTE: You can configure automatic upgrades of all COs connected to the rack console switch by checking the Auto upgrade box in the CO Status window. 3. Click the checkbox next to one or more CO types. 4. Click Upgrade. The CO
  • IBM 17353LX | User Guide - Page 76
    62 IBM Rack Console Switch Installation and User's Guide Appendix B: Technical Specifications Table B.1: Rack console switch product specifications Product Specifications Server Ports Number Cable Types Connectors Sync Types Plug and Play Video Resolution Update Port Number Type Connector Local
  • IBM 17353LX | User Guide - Page 77
    about diagnostic tools is in the Hardware Maintenance Manual and Troubleshooting Guide or Problem Determination and Service Guide on the IBM Documentation CD that comes with your server. • Go to the IBM support Web site at http://www.ibm.com/servers/eserver/support/xseries/ index.html to check for
  • IBM 17353LX | User Guide - Page 78
    64 IBM Rack Console Switch Installation and User's Guide Getting help and information from the World Wide Web On the World Wide Web, the IBM Web site has up-to-date information about IBM systems, optional devices, services, and support. The address for IBM System x™ and xSeries® information is http
  • IBM 17353LX | User Guide - Page 79
    IBM Taiwan product service contact information: IBM Taiwan Corporation 3F, No 7, Song Ren Rd. Taipei, Taiwan Telephone: 0800-016-888 Appendices 65
  • IBM 17353LX | User Guide - Page 80
    IBM Rack Console Switch Installation and User's Guide Appendix D: Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM implied warranties in
  • IBM 17353LX | User Guide - Page 81
    solely by third parties. IBM makes no representations or warranties with respect to non- IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program
  • IBM 17353LX | User Guide - Page 82
    68 IBM Rack Console Switch Installation and User's Guide on IBM product recycling offerings can be found on IBM's Internet site at http://www.ibm.com/ ibm/environment/products/prp.shtml. Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en la normativa nacional o local aplicable
  • IBM 17353LX | User Guide - Page 83
    collection and treatment, contact your local IBM representative. Battery return program This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be
  • IBM 17353LX | User Guide - Page 84
    70 IBM Rack Console Switch Installation and User's Guide Electronic emission notices Federal Communications Commission (FCC) statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
  • IBM 17353LX | User Guide - Page 85
    equipment. Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for
  • IBM 17353LX | User Guide - Page 86
    72 IBM Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 87
    emission notice 70 configuration port features and benefits 1 using to upgrade firmware 59 console switch cables access blocked status 26 connecting servers to the switch 13 connecting servers with 13 disconnected, clearing from the server list 26 hardware tests 46 installation requirements 7 PS
  • IBM 17353LX | User Guide - Page 88
    for configuring users 56 requirement for logging out current users 28 F FCC Class A notice 70 firmware console switch cable upgradability 2 console switch cable, upgrading 59 COs, enabling automatic upgrades on 61 COs, upgrading 4, 60 intelligent connectors, upgradability 2 supporting daisy
  • IBM 17353LX | User Guide - Page 89
    servers with 14 requirements for installation 7 supported 1 Keep Alive functionality 1 keyboard and mouse resetting 44 country code, configuring 51 monitor, and mouse, connecting 14 KVM conversion options See KCOs 2 L legacy switches, tiering with 4 local users, connecting 14 M Main window example
  • IBM 17353LX | User Guide - Page 90
    passwords current user configuring 38 users, configuring 56 Plug and Play 4 ports See ARI ports power cord 7 preemptive switch mode, configuring 50 Print Screen key, for accessing the OSCAR interface 23 PS/2 console switch cables supported 1 Q Quick Installation Guide 7 Quick Installation Guide for
  • IBM 17353LX | User Guide - Page 91
    chaining with 15 requirements for installation 7 support 1 United States electronic emission Class A notice 70 United States FCC Class A notice 70 update utility 59 USB console switch cable support 1 USB conversion options See UCOs usernames, configuring 56 users configuring server access 55 default
  • IBM 17353LX | User Guide - Page 92
    78 IBM Rack Console Switch Installation and User's Guide
  • IBM 17353LX | User Guide - Page 93
  • IBM 17353LX | User Guide - Page 94
    43V6019 590-701-501B
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Installation and User’s Guide
For 17353LX and 17354LX
Rack Console
Switch