LED FAN TEMP BRD PCI-A PCI-B PCI-C Problem Action When the LED is lit, a fan has failed or Replace the failing fan, which is indicated by the lit LED. If a is operating too slowly. A failing fan can configuration error has occurred, make sure that the fans are also cause the TEMP LED to be lit. installed correctly. When the LED flashes, an invalid fan configuration has occurred. The system temperature has exceeded a threshold level. v Determine whether a fan has failed. If it has, replace it. v Make sure that the air vents are not blocked. v Make sure that the room temperature is not too high. See the "Features and specifications" on page 4 for temperature information. An error has occurred on the system board or there is a battery fault An error has occurred on PCI bus A An error has occurred on PCI bus B An error has occurred on PCI bus C If the problem remains, call for service. v Check the LEDs on the system board to identify the component that is causing the error. v Check the system error log for information about the error. v Check the battery and replace it if it is defective. Check the PCI-Express Adapter in slot 2 for an error or there might be a general system board malfunction. Check the following items for errors: v PCI/PCI-X Adapter in Slots 1 or 2. v On-board SCSI. v The system board might have a malfunction. Check the on-board Ethernet controllers or check for a general system board malfunction. 68 IBM xSeries 336 Type 8837: Installation Guide