DSC OPERATION 7 DDReceiving a Distress Acknowledgment When a Distress Acknowledgment is received: •• The emergency alarm sounds until you turn it OFF. •• "Received Distress ACK" is displayed. 1. Push to turn OFF the alarm. DDReceiving a Distress Cancel call When a Distress Cancel call is received: •• The emergency alarm sounds until you turn it OFF. •• "Received Distress ACK" is displayed. 1. Push to turn OFF the alarm. 2. Push . Rotate LLWhen "Accept after 10 sec." or "Ignore after 10 sec." is selected in "CH Auto Switch" setting, the countdown is displayed on the bottom of the window. (p. 58) 7 After 10 seconds have passed since is pushed, the screen will move to the DSC Task screen, or return to the Main screen. 2. Push the Software Key below the intended operation. •• One of the Emergency Frequencies is automatically selected. Monitor it because a coast station may require assistance. •• Rotate [CH/GRP] to confirm the call contents. LLSee pages 27 and 28 for details of the Software Key functions in the DSC Task mode. 3. Push , and then to return to the Main screen. : Ignores the call and returns to the Main screen. : Puts the RX task on hold, and returns to the Main screen. : Pauses the countdown. : E nters the DSC Task mode immediately. Rotate •• One of the Emergency Frequencies is automatically selected. Monitor it because a coast station may require assistance. •• Rotate [CH/GRP] to confirm the call contents. LLSee pages 27 and 28 for details of the Software Key functions in the DSC Task mode. ► Continued on the next page 45
![](/manual_guide/products/icom-icm803-instruction-manual-64748e0/53.png)