Icom IC-M803 Instruction Manual - Page 68
Self Check Test, Procedure, Discrete, Alarm Status, MAX Distance 2-Tone
![]() |
View all Icom IC-M803 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
7 DSC OPERATION ■■DSC Settings DDAlarm Status Discrete Select whether or not to sound an alarm when receiving a lower priority DSC call while currently receiving a higher priority call. 1. Open "Alarm Status." [MENU] > DSC Settings > Alarm Status 2. Select "Discrete." Rotate + Push DDSelf Check Test The Self Check test sends DSC signals to the receiving AF circuit to compare the sending and receiving signals at the AF level. 1. Open "Self Check Test." [MENU] > DSC Settings > Self Check Test 2. Push [ENT], or to start the Self Check Test. LLWhen the sending and receiving DSC signals match, "OK" is displayed. Push 3. Select an option. Rotate + Push •• On: Alarm sounds. •• Off: Alarm does not sound. 4. Push [MENU], or to return to the Main screen. MAX Distance 2-Tone Set the max distance between vessels for the ringing of the 2-tone alarm is enabled. 1. Open "Alarm Status." [MENU] > DSC Settings > Alarm Status 2. Select "MAX Distance 2-Tone." Rotate 3. Enter the max distance. + Push Rotate DDProcedure You can select the type of task for the transceiver, depending on the presetting. 1. Open "Procedure." [MENU] > DSC Settings > Procedure 2. Select an option. Rotate + Push •• Single: Handles only 1 task at the same time. •• Multiple: Handles up to 7 tasks at the same time. + Push 4. Push [MENU], or screen. 60 to return to the Main