Icom IC-V10MR Operating Guide - Page 7

Assignable Software Key functions, Prio A Rewrite

Page 7 highlights

1 PANEL DESCRIPTION Assignable Software Key functions Disable Set to disable the key. NOTE: This key function is assignable to only [Ext. Emer]. Null No function. Scan Start/Stop While a scan is paused by detecting a signal, hold down for 1 second to temporarily remove the scan group's channel. After the scan is canceled, the removed channel automatically returns to the scan group. Prio A, Prio B Push to select the Priority A or Priority B channel. Prio A (Rewrite), Prio B (Rewrite) zz Push to select the Priority A or Priority B channel. zz Hold down for 1 second to assign the operating channel to the Priority A or Priority B channel. Moni *2 zz Hold down to unmute the channel. (Audible mode) zz Push to enter the Inaudible mode. zz Activates the function on each channel, depending on the presetting. zz Depending on the presetting, hold down for 1 second to cancel the scan. NOTE: The audible (unmuted) mode may automatically return to the Inaudible (muted) mode after the preset period of time ends. zz Depending on the presetting, holding down this key for 1 second may cancel the scan. Since FCC Part 95.2725 requires monitoring the channel before transmit, Lockout (Busy lockout) must be enabled if Moni (Monitor) button was disabled. Lone Worker Push to turn the Lone Worker function ON or OFF. LLIf no operation occurs during a specified period, the Lone Worker function automatically makes the transceiver enter the Emergency mode. NOTE: To use the Lone Worker function, set the related settings using the programming software. High/Low Push to select the transmit output power level temporarily, or permanently, depending on the presetting. DTMF Autodial Push to transmit a DTMF code set in Code No. 1. Re-dial Push to send the last transmitted DTMF code. LLRedial will be cleared when the transceiver is turned OFF once. Call Push to make a call to the preset destination in the channel. Call A (Code 1), Call B (Code 2) Push to transmit a set 2-Tone code. LLThe code is transmitted to the selected station in Call Key Assign. Emergency 1. Hold down during the Emer SW ON Timer period to enter the Emergency mode. 2. After the Reminder Timer period has passed, an Emergency call is automatically transmitted once, or repeatedly. NOTE: Set the related settings using the programming software. LLHold down during the Emer SW OFF Timer period to cancel the Emergency function, before transmitting an Emergency call. Lock Hold down for 1 second to turn the Key Lock function ON or OFF. LLAll assignable keys except the following are electronically locked: [Moni *2], [Call], [Call A (Code 1)], [Call B (Code 2)], [Emergency], [Lock], [Lone Worker], [Siren], [Surveillance], [Sp. Func 1] [Sp. Func 2], and [PTT]. You can also make or receive calls, or turn the transceiver ON or OFF, while the Key Lock function is ON. Surveillance Push to turn the Surveillance function ON or OFF. When this function is turned ON, the beep does not sound, and the backlight and the status indicator do not light, even when a signal is received, or a key is pushed. ► Continued on the next page 1-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

1
PANEL DESCRIPTION
1-5
Disable
Set to disable the key�
NOTE:
This key function is assignable to only
[Ext� Emer]�
Null
No function�
Scan Start/Stop
While a scan is paused by detecting a signal, hold
down for 1 second to temporarily remove the scan
group’s channel�
After the scan is canceled, the removed channel
automatically returns to the scan group�
Prio A, Prio B
Push to select the Priority A or Priority B channel�
Prio A (Rewrite), Prio B (Rewrite)
z
Push to select the Priority A or Priority B channel�
z
Hold down for 1 second to assign the operating
channel to the Priority A or Priority B channel�
Moni *2
z
Hold down to unmute the channel� (Audible mode)
z
Push to enter the Inaudible mode�
z
Activates the function on each channel, depending
on the presetting�
z
Depending on the presetting, hold down for 1
second to cancel the scan�
NOTE:
The audible (unmuted) mode may
automatically return to the Inaudible (muted) mode
after the preset period of time ends�
z
Depending on the presetting, holding down this key
for 1 second may cancel the scan�
Since FCC Part 95�2725 requires monitoring the
channel before transmit, Lockout (Busy lockout)
must be enabled if Moni (Monitor) button was
disabled�
Lock
Hold down for 1 second to turn the Key Lock function
ON or OFF�
L
All assignable keys except the following are electronically
locked: [Moni *2], [Call], [Call A (Code 1)], [Call B
(Code 2)], [Emergency], [Lock], [Lone Worker], [Siren],
[Surveillance], [Sp� Func 1] [Sp� Func 2], and [PTT]� You
can also make or receive calls, or turn the transceiver ON
or OFF, while the Key Lock function is ON�
Assignable Software Key functions
Lone Worker
Push to turn the Lone Worker function ON or OFF�
L
If no operation occurs during a specified period, the Lone
Worker function automatically makes the transceiver
enter the Emergency mode�
NOTE:
To use the Lone Worker function, set the
related settings using the programming software�
High/Low
Push to select the transmit output power level
temporarily, or permanently, depending on the
presetting�
DTMF Autodial
Push to transmit a DTMF code set in Code No� 1�
Re-dial
Push to send the last transmitted DTMF code�
L
Redial will be cleared when the transceiver is turned OFF
once�
Call
Push to make a call to the preset destination in the
channel�
Call A (Code 1), Call B (Code 2)
Push to transmit a set 2-Tone code�
L
The code is transmitted to the selected station in Call Key
Assign�
Emergency
1�
Hold down during the Emer SW ON Timer period
to enter the Emergency mode�
2�
After the Reminder Timer period has passed, an
Emergency call is automatically transmitted once,
or repeatedly�
NOTE:
Set the related settings using the
programming software�
L
Hold down during the Emer SW OFF Timer period to
cancel the Emergency function, before transmitting an
Emergency call�
Surveillance
Push to turn the Surveillance function ON or OFF�
When this function is turned ON, the beep does not
sound, and the backlight and the status indicator do
not light, even when a signal is received, or a key is
pushed�
► Continued on the next page