Intel SCB2 Product Guide - Page 50

Server Menu, Feature, Choices, Description, Disabled, Enabled, Disable BSP, Last State

Page 50 highlights

Security Menu (continued) Feature Choices Video Blanking Disabled Enabled Power Switch Inhibit Disabled Enabled Description Blank video when secure mode is activated. A pass word is required to unlock the system. This option only appears on the screen after a "user" password has been entered. When enabled, the power switch is inoperable. This option only appears on the screen after a "user" password has been entered. Server Menu Feature System Management Console Redirection Event Log Configuration Service Boot Assert NMI on PERR Assert NMI on SERR FRB-2 Policy BMC IRQ After Power Failure Temperature Sensor Choices Press Press Press Enable Disable Disabled Enabled Disabled Enabled Disable BSP Do not Disable BSP Retry 3 Times Disabled IRQ 5 IRQ 11 Stays Off Last State Power On Disabled Enabled POST Error Pause Platform Event Filtering Disabled Enabled Disabled Enabled Description Enters Submenu. Enters Submenu. Enters Submenu If enabled, server boots directly to System Management. If enabled, PCI bus parity error (PERR) routes to NMI. If enabled, PCI bus system error (SERR) routes to NMI. Controls the policy of the FRB-2 timeout. This option determines when the Boot Strap Processor (BSP) should be disabled if an FRB-2 error occurs. Sets the BMC IRQ. Determines the mode of operation if a power loss occurs. If enabled, the system will not boot if the ambient system temperature is outside the range specified in the Sensor Data Record (SDR). If enabled, the system will wait for user intervention on critical POST errors. Enable/Disable triggers for system sensor events inside the Baseboard Management Controller (BMC). 50 Intel Server Board SCB2 Product Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

50
Intel Server Board SCB2 Product Guide
Security Menu
(continued)
Feature
Choices
Description
Video Blanking
Disabled
Enabled
Blank video when secure mode is activated. A pass word is required
to unlock the system.
This option only appears on the screen after a “user” password has
been entered.
Power Switch
Inhibit
Disabled
Enabled
When enabled, the power switch is inoperable.
This option only appears on the screen after a “user” password has
been entered.
Server Menu
Feature
Choices
Description
System Management
Press <Enter>
Enters Submenu.
Console Redirection
Press <Enter>
Enters Submenu.
Event Log Configuration
Press <Enter>
Enters Submenu
Service Boot
Enable
Disable
If enabled, server boots directly to System
Management.
Assert NMI on PERR
Disabled
Enabled
If enabled, PCI bus parity error (PERR) routes to NMI.
Assert NMI on SERR
Disabled
Enabled
If enabled, PCI bus system error (SERR) routes to NMI.
FRB-2 Policy
Disable BSP
Do not Disable BSP
Retry 3 Times
Controls the policy of the FRB-2 timeout. This option
determines when the Boot Strap Processor (BSP)
should be disabled if an FRB-2 error occurs.
BMC IRQ
Disabled
IRQ 5
IRQ 11
Sets the BMC IRQ.
After Power Failure
Stays Off
Last State
Power On
Determines the mode of operation if a power loss
occurs.
Temperature Sensor
Disabled
Enabled
If enabled, the system will not boot if the ambient
system temperature is outside the range specified in the
Sensor Data Record (SDR).
POST Error Pause
Disabled
Enabled
If enabled, the system will wait for user intervention on
critical POST errors.
Platform Event Filtering
Disabled
Enabled
Enable/Disable triggers for system sensor events inside
the Baseboard Management Controller (BMC).