Intermec SR31T SR31T Tethered Scanner User's Guide - Page 50

Rescuing the SR31T, To rescue your SR31T

Page 50 highlights

Chapter 5 - Troubleshooting and Maintaining the SR31T Rescuing the SR31T You can rescue your SR31T if you cannot configure it anymore because it is in a locked configuration. This can happen if you inadvertently disabled the trigger for example. Note: When you rescue your scanner, factory default settings are restored including custom default settings. Rescuing the scanner is also a way to force a factory reset if you do not have access to a Reset factory defaults configuration code or a PC with EasySet. To rescue your SR31T 1 Disconnect your product from its electrical power (disconnect the cable from the product). 2 With the product disconnected, use your usual operating hand to pull and hold the trigger. 3 Do not release the trigger while you reestablish electrical power (reconnect the cable). The scanner acknowledges power-up (beeps, LEDs and vibrate alert). 4 Keep the trigger pulled around 10 seconds until the red LED lights up. 5 Pull the trigger very rapidly five times in succession while the red LED is on (you need to be quick as the red LED only stays on for 2 seconds).  The green LED comes on and the scanner beeps a reset confirmation (beep melody), then acknowledges power-up again (beeps, vibrate alert). Note: If your scanner still does not operate correctly after a rescue procedure, contact your Intermec Product Support representative (see Calling Product Support in the next section). 42 SR31T Tethered Scanner User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Chapter 5 — Troubleshooting and Maintaining the SR31T
42
SR31T Tethered Scanner User’s Guide
Rescuing the SR31T
You can rescue your SR31T if you cannot configure it anymore
because it is in a locked configuration. This can happen if you
inadvertently disabled the trigger for example.
To rescue your SR31T
1
Disconnect your product from its electrical power (disconnect the
cable from the product).
2
With the product disconnected, use your usual operating hand to
pull and hold the trigger.
3
Do not release the trigger while you reestablish electrical power
(reconnect the cable).
The scanner acknowledges power-up (beeps, LEDs and vibrate
alert).
4
Keep the trigger pulled around 10 seconds until the red LED lights
up.
5
Pull the trigger very rapidly five times in succession while the red
LED is on (you need to be quick as the red LED only stays on for 2
seconds).
The green LED comes on and the scanner beeps a reset
confirmation (beep melody), then acknowledges power-up again
(beeps, vibrate alert).
Note:
When you rescue your scanner, factory default settings are
restored including custom default settings. Rescuing the scanner is
also a way to force a factory reset if you do not have access to a
Reset
factory defaults
configuration code or a PC with EasySet.
Note
: If your scanner still does not operate correctly after a rescue
procedure, contact your Intermec Product Support representative (see
Calling Product Support
in the next section).