Menu Configuration-SET-UP MENU (cont.) 16 SCHEDULER Item PRESENT TIME PROGRAM SET SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY reset To do Adjust the clock. • For the setting procedure, see page 17. Set the Power-on/off Timer for each day. • For the setting procedure, see page 17. Restore the default setting for "SCHEDULER." Setting value NETWORK SETTING Item MAC ADDRESS IP ADDRESS SUBNET MASK DEFAULT GATEWAY DNS SERVER reset To do Display the MAC address of the monitor. Setting value Make the network setting to control the monitor from the computer in the local area network. • For details, see page 23. Restore the default setting for all the items in "NETWORK SETTING." CONTROL LOCK Activates/deactivates the Control Lock. When this function is activated, you cannot operate the monitor with the buttons on the main unit. Setting value: OFF, ON • You can use the remote control and external control while the control lock is set. To release the lock, use the remote control or the SET-UP MENU button on the main unit. REFRESH Item PIXEL SHIFT COLOR REVERSE reset To do Move picture displayed on the monitor in certain period. Reverse color of the picture displayed on the monitor. Setting value OFF, ON OFF, ON Restore the default setting for all the items in "REFRESH." POWER ON DELAY Sets the time till the power supply to the monitor's circuits starts after the power button (POWER ON button on the remote control or button on the main unit) is pressed. If you are going to turn several monitors on at the same time, it is recommended to apply different values to the monitors to control rush current. Setting value: 0 - 25 • The delay time is about 5 seconds under the setting "25". SYNC TERM. Sets the resistance of sync signal of the RGB IN terminal. Normally, select "HIGH". If you see pictures flickering or blurring on the screen because of a long connecting cord, set this to "LOW". Setting value: HIGH, LOW COOLING MODE Sets the speed of the internal cooling fans. When installing the monitor vertically, select "HIGH." Setting value: LOW, HIGH • Fan A stops when "LOW" is selected. • Fan B is always in operation while the power is on. Fan B Fan A reset Restores the default setting for all the items in the set-up menu. all reset Restores the default setting for all the items in the main menu and set-up menu (except for "LANGUAGE," "HOUR METER," "SECURITY LOCK," and "PASS ID SETTING").

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

16
Menu Configuration
—SET-UP MENU (cont.)
SCHEDULER
Item
To do
Setting value
PRESENT TIME
Adjust the clock.
• For the setting procedure, see page 17.
PROGRAM SET
Set the Power-on/off Timer for each day.
• For the setting procedure, see page 17.
SUNDAY
MONDAY
TUESDAY
WEDNESDAY
THURSDAY
FRIDAY
SATURDAY
reset
Restore the default setting for “SCHEDULER.”
NETWORK SETTING
Item
To do
Setting value
MAC ADDRESS
Display the MAC address of the monitor.
IP ADDRESS
Make the network setting to control the monitor from the computer in the local area
network.
• For details, see page 23.
SUBNET MASK
DEFAULT
GATEWAY
DNS SERVER
reset
Restore the default setting for all the items in “NETWORK SETTING.”
CONTROL LOCK
Activates/deactivates the Control Lock. When this function is activated, you cannot operate the monitor with
the buttons on the main unit.
Setting value: OFF, ON
• You can use the remote control and external control while the control lock is set. To release the lock, use
the remote control or the SET-UP MENU button on the main unit.
REFRESH
Item
To do
Setting value
PIXEL SHIFT
Move picture displayed on the monitor in certain period.
OFF, ON
COLOR
REVERSE
Reverse color of the picture displayed on the monitor.
OFF, ON
reset
Restore the default setting for all the items in “REFRESH.”
POWER ON DELAY
Sets the time till the power supply to the monitor’s circuits starts after the power button (POWER ON button
on the remote control or
button on the main unit) is pressed.
If you are going to turn several monitors on at the same time, it is recommended to apply different values to
the monitors to control rush current.
Setting value: 0 – 25
• The delay time is about 5 seconds under the setting “25”.
SYNC TERM.
Sets the resistance of sync signal of the RGB IN terminal. Normally, select “HIGH”. If you see pictures
flickering or blurring on the screen because of a long connecting cord, set this to “LOW”.
Setting value: HIGH, LOW
COOLING MODE
Sets the speed of the internal cooling fans. When installing the monitor vertically, select “HIGH.”
Setting value: LOW, HIGH
• Fan A stops when “LOW” is selected.
• Fan B is always in operation while the power is on.
reset
Restores the default setting for all the items in the set-up menu.
all reset
Restores the default setting for all the items in the main menu and set-up menu (except for “LANGUAGE,”
“HOUR METER,” “SECURITY LOCK,” and “PASS ID SETTING”).
Fan B