SYSTEM System with Remote Control Unit RM-P2580 Settings Ⅲ CAMERA FACE MONITOR LOCK LEFT AWC INT OFF TERMINATION UP RIGHT SET NOT USED NOT USED L/L ON DOWN INT LL OFF ON TERMINATION • Video synchronization selector switch (INT/LL) Set to LL (Line Lock) on all cameras, and align V.PHASE. (੬ See page 29.) • Control signal termination ON/OFF switch (TERMINATION OFF/ON) Set this to ON only on the camera placed at the end of the control signal cable. Set to OFF on all other cameras. Menu Screen Settings Ⅲ COMMUNICATION menu screen • MODE item: Set to DUPLEX • STYLE item: Set to MULTIDROP • ID item: Set the camera ID. For each camera, match the ID with the VIDEO INPUT number of the RMP2580. * Settings on the COMMUNICATION menu screen are performed using the operation buttons on the front section of the camera. MEMO Following selection of MEMORY, the settings on the COMMUNICATION menu will not be valid before the power has been turned on again. Ⅲ FUNCTION menu screen Screen for making settings related to the Auto Patrol and Auto Pan functions and display of text. 14 • Settings on the FUNCTION menu are performed using the operation buttons on the RM-P2580. They cannot be made using the operation buttons on the camera body. • Make settings on other menus as required. MEMO When operating a system using the RMP2580, several cameras (up to 16) can be connected and used on one control signal cable. Consequently, an incorrect switch setting on just a single camera will cause the entire system to work incorrectly. • Confirm switch settings on the screen as follows. q Confirm that the image from the camera to be checked is displayed on the monitor. w Turn OFF and then ON the power to the camera to be checked. e When the STYLE item is MULTIDROP, characters similar to those shown in the figure below are displayed for about 5 seconds. They do not appear in the case of POINT to POINT. r Confirm that "DUPLEX" and "ID-MM" are displayed and that the ID number is the correct number (the number should be the same as the number of the VIDEO INPUT terminal to which the camera is connected on the rear panel of the RM-P2580). t If wrong, set the MODE item, STYLE item and camera ID again. MONITOR screen Monitor screen (example showing camera ID as "05") PROTO CO L : DUP L E X I D - 0 5 "DUPLEX" should be displayed. The number shown in the MM part of IDMMshould be correct.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

14
Settings
±
CAMERA FACE
Video synchronization selector switch
(INT/LL)
Set to LL (Line Lock) on all cameras, and
align V.PHASE.
(
²
See page 29.)
Control signal termination ON/OFF switch
(TERMINATION OFF/ON)
Set this to ON only on the camera placed
at the end of the control signal cable.
Set to OFF on all other cameras.
Menu Screen Settings
±
COMMUNICATION menu screen
MODE item: Set to DUPLEX
STYLE item: Set to MULTIDROP
ID item:
Set the camera ID.
For each camera, match the ID with the
VIDEO INPUT number of the RM-
P2580.
* Settings on the COMMUNICATION
menu screen are performed using the
operation buttons on the front section
of the camera.
MEMO
Following selection of MEMORY, the settings
on the COMMUNICATION menu will not be
valid before the power has been turned on
again.
±
FUNCTION menu screen
Screen for making settings related to the
Auto Patrol and Auto Pan functions and
display of text.
The number shown in
the
MM
part of ID-
MM
should be correct.
NOT USED
NOT USED
MONITOR
LOCK
LEFT
RIGHT
SET
UP
DOWN
ON
LL
OFF
TERMINATION
INT
L/L
ON
INT
OFF
TERMINATION
AWC
PROT
O
O
L: DUPLEX
ID-05
C
MONITOR screen
DUPLEX
should be
displayed.
Settings on the FUNCTION menu are
performed using the operation buttons
on the RM-P2580. They cannot be
made using the operation buttons on
the camera body.
Make settings on other menus as
required.
Monitor screen (example showing camera ID as
05
)
SYSTEM
System with Remote Control Unit RM-P2580
MEMO
When operating a system using the RM-
P2580, several cameras (up to 16) can be
connected and used on one control signal
cable. Consequently, an incorrect switch
setting on just a single camera will cause
the entire system to work incorrectly.
Confirm switch settings on the screen
as follows.
q
Confirm that the image from the camera
to be checked is displayed on the monitor.
w
Turn OFF and then ON the power to the
camera to be checked.
e
When the STYLE item is MULTIDROP,
characters similar to those shown in the
figure below are displayed for about 5
seconds. They do not appear in the case
of POINT to POINT.
r
Confirm that
DUPLEX
and
ID-
MM
are
displayed and that the ID number is the
correct number (the number should be the
same as the number of the VIDEO INPUT
terminal to which the camera is connected
on the rear panel of the RM-P2580).
t
If wrong, set the MODE item, STYLE item
and camera ID again.