Ceiling Installation 1. φ75 Ceiling mount bracket Screws 2. Tab Guide Screws Tab Guide Connector Connector cable 3. 1. Make a hole (75 mm diameter) in the ceiling for passing the connection cables, and attach the provided ceiling mount to the ceiling. Coincide the center of the mount with the hole (75 mm diameter) for passing the cables through the ceiling. Attach the ceiling mount to the ceiling using 4 screws. Pass the wired terminal board through the hole in the center of the ceiling mount and leave if hanging down. • Use M4 screws or bolts for attaching the ceiling mount. • If wood screws are used, use screws with a diameter of 4.1 mm. • The screw head height should be no more than 4 mm. 2. Attach the wired terminal board to the camera. 1) Slide the tab on the terminal board into the guide on the camera. When the terminal board is moved in the direction of the arrow, it is secured to the camera. 2) Connect the connector cable from the camera body to the connector on the terminal board. 3. Attach the drop prevention wire. As shown in the illustration, pull the drop prevention wire out from the ceiling mount and attach it to the drop prevention wire hook on the underside of the camera body. Drop prevention wire CAUTION Drop prevention wire hook Be sure to attach the drop prevention wire. If not attached, the camera body could drop down. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

17
Ceiling Installation
1.
Make a hole (75 mm diameter) in the
ceiling for passing the connection
cables, and attach the provided ceiling
mount to the ceiling.
Coincide the center of the mount with
the hole (75 mm diameter) for passing
the cables through the ceiling. Attach the
ceiling mount to the ceiling using 4
screws.
Pass the wired terminal board through
the hole in the center of the ceiling
mount and leave if hanging down.
Use M4 screws or bolts for attaching
the ceiling mount.
If wood screws are used, use screws
with a diameter of 4.1 mm.
The screw head height should be no
more than 4 mm.
2.
Attach the wired terminal board to the
camera.
1) Slide the tab on the terminal board
into the guide on the camera. When
the terminal board is moved in the
direction of the arrow, it is secured to
the camera.
2) Connect the connector cable from
the camera body to the connector on
the terminal board.
3.
Attach the drop prevention wire.
As shown in the illustration, pull the drop
prevention wire out from the ceiling
mount and attach it to the drop preven-
tion wire hook on the underside of the
camera body.
CAUTION
Be sure to attach the drop prevention wire.
If not attached, the camera body could
drop down.
Drop prevention
wire hook
1.
2.
3.
Ceiling mount
bracket
φ
75
Screws
Screws
Tab
Tab
Guide
Guide
Connector
Connector
cable
Drop prevention wire