Kodak BC4601 Service Manual - Page 10

Replacing the THERMAL FUSE ASSEMBLY, Replacing the LAMP MODULE RECEPTACLE

Page 10 highlights

SERVICE MANUAL Replacing the THERMAL FUSE ASSEMBLY Warning Dangerous Voltage [1] Disconnect the main power. [2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY. [3] Cut and remove the necessary WIRE TIES. [4] Remove the black wire from the THERMAL FUSE ASSEMBLY on the POWER SWITCH. [5] Remove the gray wire from the THERMAL FUSE ASSEMBLY from the POWER CORD. [6] Loosen the Torx SCREW on the PREHEAT DUCT approximately half way. [7] Pull the THERMAL FUSE ASSEMBLY out of hole of the LOWER LIGHT BAFFLE ASSEMBLY. Installing the THERMAL FUSE ASSEMBLY [1] Do the replacement procedure for the THERMAL FUSE ASSEMBLY in reverse order. SCREW PRE-HEAT DUCT A100_0015GCA A100_0015GA THERMAL FUSE POWER SWITCH Replacing the LAMP MODULE RECEPTACLE Warning Dangerous Voltage [1] Disconnect the main power. [2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY. [3] Cut and remove the necessary WIRE TIES. [4] Remove the 2 Torx SCREWS on the left side of the LOWER LIGHT BAFFLE ASSEMBLY. [5] Loosen the Torx SCREW on the right side of the LOWER LIGHT BAFFLE ASSEMBLY approximately 1/2 way. 10 18NOV97 - SM5440-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

SERVICE MANUAL
10
18NOV97 – SM5440-1
Replacing the THERMAL FUSE ASSEMBLY
Warning
Dangerous Voltage
[1]
Disconnect the main power.
[2]
Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3]
Cut and remove the necessary WIRE TIES.
[4]
Remove the black wire from the THERMAL FUSE ASSEMBLY on the POWER SWITCH.
[5]
Remove the gray wire from the THERMAL FUSE ASSEMBLY from the POWER CORD.
[6]
Loosen the
Torx
SCREW on the PREHEAT DUCT approximately half way.
[7]
Pull the THERMAL FUSE ASSEMBLY out of hole of the LOWER LIGHT BAFFLE ASSEMBLY.
Installing the THERMAL FUSE ASSEMBLY
[1]
Do the replacement procedure for the THERMAL FUSE ASSEMBLY in reverse order.
Replacing the LAMP MODULE RECEPTACLE
Warning
Dangerous Voltage
[1]
Disconnect the main power.
[2]
Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3]
Cut and remove the necessary WIRE TIES.
[4]
Remove the 2
Torx
SCREWS on the left side of the LOWER LIGHT BAFFLE ASSEMBLY.
[5]
Loosen the
Torx
SCREW on the right side of the LOWER LIGHT BAFFLE ASSEMBLY approximately 1/2 way.
A100_0015GA
SCREW
PRE-HEAT DUCT
THERMAL FUSE
POWER SWITCH
A100_0015GCA