Kodak BC4601 Service Manual - Page 8

Replacing the WORM PULLEY and MECHANISM BELT, Move the TAB on the WORM PULLEY ASSEMBLY out.

Page 8 highlights

SERVICE MANUAL FAN BELT MECHANISM BELT Replacing the WORM PULLEY and MECHANISM BELT A091_4015BCA A091_4015BA Warning Dangerous Voltage [1] Disconnect the main power. [2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY. [3] Do the replacement procedure for the MOTOR except do not disconnect the wires from the MOTOR. [4] Remove the Torx SCREW from the WORM PULLEY ASSEMBLY. [5] Move the TAB on the WORM PULLEY ASSEMBLY out. [6] Remove the WORM PULLEY ASSEMBLY and MECHANISM BELT. 8 18NOV97 - SM5440-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

SERVICE MANUAL
8
18NOV97 – SM5440-1
Replacing the WORM PULLEY and MECHANISM BELT
Warning
Dangerous Voltage
[1]
Disconnect the main power.
[2]
Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3]
Do the replacement procedure for the MOTOR except do not disconnect the wires from the MOTOR.
[4]
Remove the
Torx
SCREW from the WORM PULLEY ASSEMBLY.
[5]
Move the TAB on the WORM PULLEY ASSEMBLY out.
[6]
Remove the WORM PULLEY ASSEMBLY and MECHANISM BELT.
A091_4015BA
A091_4015BCA
MECHANISM BELT
FAN BELT