Page 242 highlights
6.4 When a message appears to replace consumables or carry out cleaning 6 6.4.3 Replacing a Drum Unit 1 2 3 2 1 6 5 4 1 2 Troubleshooting Chapter 6 1 2 3 4 Tips - After Drum Unit replacement step 1 has been completed, check that the circled lock is located at the position indicated by a dashed line, then execute step 2. If the circled lock is not located at the position indicated by a dashed line, press in the blue knob of the Drum Unit to release the lock. - Your service representative will collect your used Drum Unit. Put it in a black plastic bag and store it in a box by itself. - A Drum Unit may be damaged due to exposure to light. Do not take a Drum Unit out of a black plastic bag until just before it is to installed. - If a Drum Unit was replaced, be sure to adjust the gradation. For details on how to adjust the gradation, refer to the User's Guide CD. 7CAUTION - The inside of this product has areas subject to high temperature, which may cause burns. When checking the inside of the unit for malfunctions such as a paper misfeed, do not touch the locations (around the fusing unit, etc.) which are indicated by a "Caution HOT" caution label. A burn could result. bizhub 367/287/227 6-11