Lantronix MatchPort b/g MatchPort b/g - Integration Guide - Page 13
Power, Ground, and Reset, Absolute Maximum Ratings, Recommended Operating Conditions, Reset, Parameter
![]() |
View all Lantronix MatchPort b/g manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
2: Description and Specifications Power, Ground, and Reset Table 2-5. Power, Ground, and Reset Pins Power Pin 37 Ground Pin 2 Pin 39 Reset Pin 1 Driving the Reset In line low resets the MatchPort b/g. Minimum reset pulse width is 2 ms at IIL = -500uA. Absolute Maximum Ratings Table 2-6. Absolute Maximum Ratings Parameter Supply Voltage Input Voltage Output Voltage Operating Temperature Storage Temperature Min 3.135 -0.5 -0.5 -40 -40 Max 3.6 6 6 70 85 Units V V V ºC ºC Recommended Operating Conditions The following table illustrates the optimal and recommended operating conditions for the MatchPort b/g device. Table 2-7. Operating Conditions, Serial Ports, & Configurable Pins Parameter Supply Voltage Voltage Ripple VIL Input Low Voltage* VIH Input High Voltage* II Input Leakage Current* VOL Output Low Voltage @ IOL max* VOH Output High Voltage @ IOH max* TXDx, RTSx IOL Low Level Output Current @ VOL 0.4V CP1-CP8 Low Level Output Current @VOL 0.4V TXDx, RTSx IOH High Level Output Current @ VOH 2.4V CP1-CP8 IOH High Level Output Current @ VOH 2.4V * For UART and CP pins Min 3.135 -0.3 2 2.4 2.2 4.4 -3.2 -3.2 Typical 3.3 +/- 10 nA 3.5 Max 3.45 2 0.8 5.5 +/- 1 µA 0.4 4.3 Units V % V V V V mA 7.1 8.5 mA -6.4 -10.0 mA -6.4 -10.0 mA MatchPort b/g Integration Guide 13
![](/manual_guide/products/lantronix-matchport-bg-matchport-bg-integration-guide-aa1cb4c/13.png)