Lantronix UDS-10 UDS-10 / UDS100 - User Guide - Page 23
Using the Serial Port, UDS10/UDS100 User Guide, Configuring the UDS Using Telnet or the Serial Port - diagnostic
View all Lantronix UDS-10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
UDS10/UDS100 User Guide Configuring the UDS Using Telnet or the Serial Port Figure 5-2. Setup Mode 3. Select an option on the Change Setup menu by entering the number of the option in the Your choice ? prompt and pressing Enter. 4. To enter a value for a parameter, type the value and press Enter. To confirm a current value, just press Enter. 5. When you are finished, save the new configurations (option 9). The unit reboots. Using the Serial Port For local configuration, connect a terminal or a PC running a terminal emulation program to the unit's serial port (channel 1). Configure the terminal (or emulation) for 9600 baud, 8-bit, no parity, one stop bit, and no flow control. 1. Cycle the unit's power (power off and back on). After power-up, the self-test begins and the diagnostic and status LEDs start blinking. 23