Lantronix xDirect xDirect - User Guide - Page 45
a) Incoming Connection
View all Lantronix xDirect manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
8: Setup Mode: Channel Configuration Note: All bit positions in the table that are blank represent "don't care" bits for that particular option, which can be set to either a 0 or 1 value. Table 8-6 Connect Mode Options Connect Mode Option a) Incoming Connection Never accept incoming Accept with active Modem Control In Always Accept b) Response Nothing (quiet) Character response (C=connect, D=disconnect, N=unreachable) c) Active Startup No active startup With any character With active Modem Control In With a specific start character Manual connection Autostart Hostlist d) Datagram Type Directed UDP e) Modem Mode No Echo Data Echo & Modem Response (Numeric) Data Echo & Modem Response (Verbose) Modem Response Only (Numeric) Modem Response Only (Verbose) 76543210 000 010 110 0 1 0000 0001 0010 0011 0100 0101 0010 1100 00 01 11 11 1 01 110 001111 001110 a) Incoming Connection Never Accept Incoming Accept with active Modem Control in Always Accept Rejects all external connection attempts. Accepts external connection requests only when Modem Control In input is asserted. Cannot be used with Modem Mode. Accepts any incoming connection when a connection is not already established. Default setting. xDirect User Guide 45