Page 109 highlights
Set Timer Control Input Field Major Function Number - 22 Minor Function Number - 3 Parameter 1 - Bits 15-8 Reserved Bits 7- Timer control Bit - System (Hibernation/suspend) timer = : Disable = 1 : Enable Bit 1 - Standby timer = : Disable = 1 : Enable Bit 2 - LCD off timer = : Disable = 1 : Enable Bit 3 - HDD off timer = : Disable = 1 : Enable Bits 7-4 - Reserved Parameter 2 - Reserved Parameter 3 - Reserved Parameter 4 - Reserved Parameter 5 - Reserved Output Field Return Code - Error status Auxiliary Return Code - Reserved Parameter 1 - Reserved Parameter 2 - Reserved Reserved Parameter 3 - Reserved Parameter 4 - Reserved Parameter 5 - Reserved SMAPI BIOS B-33
Set Timer Control
Input Field
Major Function Number - 22
Minor Function Number - 3
Parameter 1
- Bits 15-8 Reserved
Bits 7- Timer control
Bit
- System
(Hibernation/suspend) timer
=
: Disable
= 1 : Enable
Bit 1 - Standby timer
=
: Disable
= 1 : Enable
Bit 2 - LCD off timer
=
: Disable
= 1 : Enable
Bit 3 - HDD off timer
=
: Disable
= 1 : Enable
Bits 7-4 - Reserved
Parameter 2
- Reserved
Parameter 3
- Reserved
Parameter 4
- Reserved
Parameter 5
- Reserved
Output Field
Return Code
- Error status
Auxiliary Return Code - Reserved
Parameter 1
- Reserved
Parameter 2
- Reserved
Reserved
Parameter 3
- Reserved
Parameter 4
- Reserved
Parameter 5
- Reserved
SMAPI BIOS