Lenovo ThinkPad Edge E431 Hardware Maintenance Manual - Page 46

Numeric error codes, If no numeric code is displayed

Page 46 highlights

• "Undetermined problems" on page 43 The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most likely cause is listed first, in boldface type. Note: Do the FRU replacement or other actions in the sequence shown in the column headed "FRU or action, in sequence." If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU. This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next. A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number. If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to "Intermittent problems" on page 43. Note: For a device not supported by diagnostic codes in the ThinkPad notebooks, see the manual for that device. Numeric error codes Table 2. Numeric error codes Symptom or error (beeps, if any) FRU or action, in sequence 0177 Bad SVP data, stop POST task-The checksum of the supervisor password in the EEPROM is not correct. Replace the system board. 0183 Bad CRC of Security Settings in EFI Variable. Enter the ThinkPad Setup program. - The checksum of the Security settings in the EFI Variable is not correct. 1. Run the ThinkPad Setup program. The settings will be corrected automatically. Then save the current settings by pressing Fn+F10. 2. Replace the system board. 0187 Replace the system board. EAIA data access error - The access to EEPROM is failed. 0188 Invalid RFID Serialization Information Area. Replace the system board. 0189 Replace the system board. Invalid RFID configuration information area - The EEPROM checksum is not correct. 0190 Critical low-battery error 0191 System Security - Invalid Remote Change requested. 0199 System Security - Security password retry count exceeded. 1. Charge the battery pack. 2. Replace the battery pack. 1. Run the ThinkPad Setup program, and then save current setting by pressing Fn+F10. 2. Replace the system board. 1. Run the ThinkPad Setup program. The retry count will be reset. Then save the current settings by pressing Fn+F10. 2. Replace the system board. 40 Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

“Undetermined problems” on page 43
The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most
likely cause is listed first, in boldface type.
Note:
Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or
action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the
computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be
replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays,
n
can
be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not
described there, go to “Intermittent problems” on page 43.
Note:
For a device not supported by diagnostic codes in the ThinkPad notebooks, see the manual for
that device.
Numeric error codes
Table 2. Numeric error codes
Symptom or error (beeps, if any)
FRU or action, in sequence
0177
Bad SVP data, stop POST task—The checksum of the
supervisor password in the EEPROM is not correct.
Replace the system board.
0183
Bad CRC of Security Settings in EFI Variable. Enter the
ThinkPad Setup program. – The checksum of the Security
settings in the EFI Variable is not correct.
1.
Run the ThinkPad Setup program. The settings
will be corrected automatically. Then save the
current settings by pressing Fn+F10.
2. Replace the system board.
0187
EAIA data access error - The access to EEPROM is failed.
Replace the system board.
0188
Invalid RFID Serialization Information Area.
Replace the system board.
0189
Invalid RFID configuration information area - The EEPROM
checksum is not correct.
Replace the system board.
0190
Critical low-battery error
1.
Charge the battery pack.
2. Replace the battery pack.
0191
System Security - Invalid Remote Change requested.
1.
Run the ThinkPad Setup program, and then save
current setting by pressing Fn+F10.
2. Replace the system board.
0199
System Security - Security password retry count
exceeded.
1.
Run the ThinkPad Setup program. The retry count
will be reset. Then save the current settings by
pressing Fn+F10.
2. Replace the system board.
40
Hardware Maintenance Manual