LevelOne FCS-4041 User Manual

LevelOne FCS-4041 Manual

LevelOne FCS-4041 manual content summary:

  • LevelOne FCS-4041 | User Manual - Page 1
    FCS-4041 Day/Night H.264 2-Megapixel PoE IP Dome Camera User Manual Ver1.0 1
  • LevelOne FCS-4041 | User Manual - Page 2
    Table of Contents 1. Overview ...4 1.1 Features ...4 1.2 Package Contents ...5 1.3 Dimensions...6 1.4 Switch/Connector Definition 7 2. Camera Cabling...8 2.1 Connect Power...8 2.2 Connect Ethernet Cable 8 2.3 Apply Alarm I/O ...9 2.4 Apply Audio ...9 3. System Requirements ...10 4. Access Camera
  • LevelOne FCS-4041 | User Manual - Page 3
    7.2.20 Maintenance 56 7.3 Streaming...57 7.3.1 Video Format (Video Resolution/ Video Deinterlace 57 7.3.2 Video Compression 60 7.3.3 Video OCX Protocol 61 7.3.4 Video Frame Rate 62 7.3.5 Audio (Audio Mode and Bit Rate Settings 63 7.4 PTZ...64 7.4.1 Preset ...64 7.4.2 Cruise ...65
  • LevelOne FCS-4041 | User Manual - Page 4
    and audio data using wire connection. Live video can be monitored and recorded from window-based computer via network. The video encoder supports real-time Main Profile H.264 Full HD resolution. Simultaneous dual streams, H.264/H.264 and H.264/MJPEG, are available for various network applications
  • LevelOne FCS-4041 | User Manual - Page 5
    Dome Camera with Outdoor Mount Kit M3 Standard Screw (x1) M3 Security Screw (x1)☆ M5 Standard Screw (x1) M5 Security Screw (x1) ☆ Waterproof Rubber Quick Guide CD: Operation Manuals Optical Cover Lubricant *Optional: For Vandal Proof Cover only. Security Torx ☆ 5
  • LevelOne FCS-4041 | User Manual - Page 6
    1.3 Dimensions Outdoor 6
  • LevelOne FCS-4041 | User Manual - Page 7
    1.4 Switch/Connector Definition There are various connectors located on the Dome Camera's back plate as shown in the figures below. Please refer to the diagrams and tables accompanied with for use of each switch/connector. Outdoor A RJ-45 Connector B ALARM I/O C Power D Micro SD Card Slot E Factory
  • LevelOne FCS-4041 | User Manual - Page 8
    2. 2.1 2.2 Camera Cabling Please follow the instructions below to complete network Speed Dome Camera connection. Connect Power Please refer to the illustrations below to connect power core through the supplied power adaptor.
  • LevelOne FCS-4041 | User Manual - Page 9
    2.3 Apply Alarm I/O The network Speed Dome Camera supports 4 digital alarm inputs and 2 digital alarm outputs. Please make sure the alarm connections are properly wired before starting to configure alarm related settings on this "
  • LevelOne FCS-4041 | User Manual - Page 10
    3. System Requirements To perform the network Speed Dome Camera via web browser, please ensure your PC is in good network connection, and meet system requirement as described below. Items Personal Computer Operating System Web Browser Network Card Viewer Minimum Requirement 1. Intel® Pentium® IV,
  • LevelOne FCS-4041 | User Manual - Page 11
    4. Access Camera For initial access to the network Speed Dome Camera, users can search the camera through the installer program: DeviceSearch.exe, which can be found in "Device Search" folder in the supplied CD. Device Search Software Setup Step 1: Double click on the program Device Search.exe.
  • LevelOne FCS-4041 | User Manual - Page 12
    Additionally, users can change the network Speed Dome Camera's network property, either DHCP or Static IP directly in the device finding list. Refer to the following section for changing the network Speed Dome Camera's network property. Example of Changing IP Camera's Network Property Users can
  • LevelOne FCS-4041 | User Manual - Page 13
    The Information Bar (just below the URL bar) may come out and ask for permission to install the ActiveX Control for displaying video in browser. Right click on the Information Bar and select to allow the installation. Then the security warning window will pop up. Click
  • LevelOne FCS-4041 | User Manual - Page 14
    5. Setup Video Resolution Users can setup Video Resolution on Video Format page of the user-friendly browser-based configuration interface. Video Format can be found under this path: Streaming> Video Format. 14
  • LevelOne FCS-4041 | User Manual - Page 15
    x 1080 (15fps) 1280 x 1024 (30fps) 1280 x 720 (30fps) 1024 x 768 (30fps) 800 x 600 (30fps) 720 x 480 (30fps) MJPEG+ H.264 H.264 BNC SUPPORT 720 x 480 (30fps)* √ 640 x 480 (30fps) √ 352 x 240 (30fps) √ 1920 x 1080 (15fps) √ 1280 x 1024 (30fps) √ 1280 x 720 (30fps) √ 1024 x 768 (30fps
  • LevelOne FCS-4041 | User Manual - Page 16
    x 720 (30fps) 1024 x 768 (30fps) 800 x 600 (30fps) 720 x 480 (30fps) 640 x 480 (30fps) √ 352 x 240 (30fps) √ H.264 + H.264 H.264-2 BNC SUPPORT 720 x 480 (30fps)* √ 640 x 480 (30fps) √ 352 x 240 (30fps) √ 1920 x 1080 (15fps) √ 1280 x 1024 (30fps) √ 1280 x 720 (30fps) √ 1024 x 768
  • LevelOne FCS-4041 | User Manual - Page 17
    (30fps) √ 1280 x 720 (30fps) √ 1024 x 768 (30fps) √ 800 x 600 (30fps) √ 720 x 480 (30fps) √ 640 x 480 (30fps) √ H.264 ONLY H.264 BNC SUPPORT 1920 x 1080 (30fps) √ 1280 x 1024 (30fps) √ 1280 x 720 (30fps) √ 1024 x 768 (30fps) √ 800 x 600 (30fps) √ 720 x 480 (30fps) √ 640
  • LevelOne FCS-4041 | User Manual - Page 18
    and audio data using wire connection. Live video can be monitored and recorded from window-based computer via network. The video encoder supports real-time Main Profile H.264 Full HD resolution. Simultaneous dual streams, H.264/H.264 and H.264/MJPEG, are available for various network applications
  • LevelOne FCS-4041 | User Manual - Page 19
    information of each item is as described in the following chapter. Function Items on Home Page Multiple Languages Support Multiple languages are supported, including German, English, French, Italian, Korean, Simplified Chinese, Russian, etc. for the viewer window interface. Digital Zoom Control
  • LevelOne FCS-4041 | User Manual - Page 20
    and continuously regardless of zoom changes or any view changes. The Focus status will also be displayed above the live video pane as shown below.  Manual button Click on the button, and users can adjust focus
  • LevelOne FCS-4041 | User Manual - Page 21
    Near/Far buttons.  Near/Far buttons Click on the button, and users can adjust focus manually via and buttons. The status will also be displayed above the screen as shown below Pan/Tilt Control Users can implement pan/tilt
  • LevelOne FCS-4041 | User Manual - Page 22
    7.2 System Under the tab , there are categories as the table below: System System Security Network DDNS Mail FTP HTTP Application Motion Detection Tampering Storage Management Recording File Location View Log File View User Information View Parameters Factory Default Software Version
  • LevelOne FCS-4041 | User Manual - Page 23
    enter "01:00:00" into the field. Sync With Computer Time Select the item and video date and time display will synchronize with the PC's. Manual The Administrator can set video date, time and day manually. Entry format should be identical with that shown next to the enter field. 23
  • LevelOne FCS-4041 | User Manual - Page 24
    Sync with NTP Server Network Time Protocol (NTP) is an alternate way to synchronize your camera's clock with a NTP server. Please specify the server you wish to synchronize in the enter field. Then select an update interval from the drop-down menu. For further information about NTP, please see the
  • LevelOne FCS-4041 | User Manual - Page 25
     I/O access This item supports fundamental functions that enable users to view video when accessing to the camera.  Camera control This item allows the appointed User to change camera parameters
  • LevelOne FCS-4041 | User Manual - Page 26
    7.2.2.2 HTTPS The HTTPS setting can be found under this path: System> Security> HTTPS. allows secure connections between the IP Camera and web browser using or , which ensure camera settings or Username/ Password info from snooping.
  • LevelOne FCS-4041 | User Manual - Page 27
    certificate. Provide the Certificate Information To create a Self-signed HTTPS Certificate or a Certificate Request to CA, please enter the information as requested: Country State or Province Locality Organization Organizational Unit Common Name Valid Day Create Self Signed Certificate Create
  • LevelOne FCS-4041 | User Manual - Page 28
    7.2.2.3 IP Filter The IP Filter setting can be found under this path: System> Security> IP Filter. Using the IP filter, access to the IP Camera can be restricted by denying/allowing specific IP addresses.  Enable IP Filter Check the box to enable the IP Filter function. Once enabled, the listed IP
  • LevelOne FCS-4041 | User Manual - Page 29
     Add/ Delete IP Address Input the IP address and click on the button to add a new filtered address. The Filtered IP Addresses list box shows the currently configured IP addresses. Up to 256 IP address entries may be specified. To remove an IP address from the list, please select the IP and
  • LevelOne FCS-4041 | User Manual - Page 30
    Check the box to enable IEEE 802.1X. Click on to save the IEEE 802.1X/ EAP- TLS setting. 30
  • LevelOne FCS-4041 | User Manual - Page 31
    with fixed or dynamic (DHCP) IP address. The IP Camera also provides PPPoE support for users who connect to the network via PPP over Ethernet (PPPoE). General 's default setting is . Please refer to User's Manual for login with the default IP address. If select
  • LevelOne FCS-4041 | User Manual - Page 32
    This is necessary for network identification.  Subnet mask It is used to determine if the destination is in the same subnet. The default value is "255.255.255.0".  Default gateway This is the gateway used to forward frames to destinations in different subnet. Invalid gateway setting will fail the
  • LevelOne FCS-4041 | User Manual - Page 33
    1024 to 65535. NOTE: Be aware to choose the different port from the one set for the web server port. IPv6 Address Configuration With IPv6 support, users can use the corresponding IPv6 address for browsing. Enable IPv6 by checking the box and click on to complete the setting. 33
  • LevelOne FCS-4041 | User Manual - Page 34
    guarantees delivery of priority services especially when network congestion occurs. Adapting the Differentiated Services (DiffServ) model, HTTP.  Audio DSCP This setting is only available for the IP Cameras that support audio.  Management DSCP The class consists of HTTP traffic: Web browsing.
  • LevelOne FCS-4041 | User Manual - Page 35
    SNMP The SNMP (Simple Network Management Protocol) setting can be found under this path: System> Network> SNMP. With Simple Network Management Protocol (SNMP) support, the IP Camera can be monitored and managed remotely by the network management system. SNMP v1/ v2  Enable SNMP v1/ v2 Select the
  • LevelOne FCS-4041 | User Manual - Page 36
    IP Camera is allowed to open the web server port on the router automatically. NOTE: To enable this function, please make sure that your router supports UPnP and it is activated.  Friendly name Set the name for the IP Camera for identity. 36
  • LevelOne FCS-4041 | User Manual - Page 37
    7.2.4 DDNS The DDNS setting can be found under this path: System> DDNS. Dynamic Domain Name System (DDNS) allows a host name to be constantly synchronized with a dynamic IP address. In other words, it allows those using a dynamic IP address to be associated to a static domain name so others can
  • LevelOne FCS-4041 | User Manual - Page 38
    sets of SMTP can be configured. Each set includes SMTP Server, Account Name, Password and E-mail Address settings. For SMTP server, contact your network service provider for more specific information. 7.2.6 FTP The FTP setting can be found under this path: System> FTP. The Administrator can set as
  • LevelOne FCS-4041 | User Manual - Page 39
    7.2.7 HTTP The HTTP setting can be found under this path: System> HTTP. A HTTP Notification server can listen for notification messages from IP Cameras by triggered events. Enter the HTTP details, which include server name (for instance, http://192.168.0.1/admin.php), user name, and password in the
  • LevelOne FCS-4041 | User Manual - Page 40
    Application. The Camera equips four alarm inputs and two relay outputs for cooperating with alarm system to catch events' images. Please refer to User's Manual for Alarm Pin Definition to connect the alarm devices. Alarm Pin Selection Select an alarm pin which is to be configured from the
  • LevelOne FCS-4041 | User Manual - Page 41
     Upload Image by E-Mail Select this item and the Administrator can assign an e-mail address and configure various parameters. When the alarm is triggered, event images will be sent to the appointed e-mail address. NOTE: Make sure SMTP or FTP configuration has been completed. Please refer to section
  • LevelOne FCS-4041 | User Manual - Page 42
     Record Stream to SD Card Select the item and the alarm-triggered recording will be saved into your Micro SD card. Pre-trigger buffer recording function allows users to check what happened to cause the trigger. The pre-trigger buffer time range is from 1 to 3 seconds. Select to set
  • LevelOne FCS-4041 | User Manual - Page 43
     Overwrite The original image in the FTP site will be overwritten by the new uploaded file with a static filename. Save After complete all the settings mentions above, please click on the button to save all the settings on this page. 7.2.9 Motion Detection The Motion Detection setting can be
  • LevelOne FCS-4041 | User Manual - Page 44
    If Motion Detection function is activated, the pop-out window (Motion) with indication of motion will be shown. When motion is detected, the signals will be displayed on the Motion window as shown below. Motion Detection Users are able to turn on/off Motion Detection. Default setting is Off. Motion
  • LevelOne FCS-4041 | User Manual - Page 45
    Triggered Action (Multi-option) The Administrator can specify alarm actions that will take when motion is detected. All options are listed as follows:  Enable Alarm Output 1/2 Check the item and select the predefined type of alarm output to enable alarm relay output when motion is detected.  Send
  • LevelOne FCS-4041 | User Manual - Page 46
    File Name The uploaded image's filename format can be set in this section. Please select the one that meets your requirements. Save Click on the button to save all the Motion Detection settings mentioned above. 7.2.10 Tampering The Tampering setting can be found under this path: System>
  • LevelOne FCS-4041 | User Manual - Page 47
    Tampering Alarm Users are able to turn on/off Tampering Alarm function in Tampering Alarm setting page. The default setting is Off. Tampering Duration Minimum Tampering Duration is the time for video analysis to determine whether camera tampering has occurred. Minimum Duration could also be
  • LevelOne FCS-4041 | User Manual - Page 48
     Upload Image by E-Mail Select this item and the Administrator can assign an e-mail address and configure various parameters. When tampering is detected, event images will be sent to the appointed e-mail address. NOTE: Make sure SMTP or FTP configuration has been completed. Refer to Mail and FTP
  • LevelOne FCS-4041 | User Manual - Page 49
    This page shows the capacity information of the Micro SD card and a recording list with all the recording files saved on the memory card. Users can also format the SD card and implement automatic recording cleanup through the setting page. To implement Micro SD card recording, please go to the <
  • LevelOne FCS-4041 | User Manual - Page 50
    Recording List Each video file on the Micro SD/SDHC card will be listed in the Recording list. The maximum file size is 60 MB/per file When the recording mode is set as (consecutive recording) and the Micro SD/ SDHC card recording is also allowed to be enabled by events triggered, once
  • LevelOne FCS-4041 | User Manual - Page 51
    7.2.12 Recording (Local Recording) The Recording setting can be found under this path: System> Recording. In the Recording setting page, users can specify the recording schedule that fits the present surveillance requirement. Activating Micro SD/SDHC Card Recording Two types of schedule mode are
  • LevelOne FCS-4041 | User Manual - Page 52
    NOTE: For users with Windows 7 operating system, it is required to log on as an Administrator to implement the Snapshot and Web Recording function. 7.2.14 View Log File The View Log File function can be found under this path: System> View Log File. Click on the link to view the system log file. The
  • LevelOne FCS-4041 | User Manual - Page 53
    Click on at the bottom of the page, and the Administrator can view each user's privileges as "User: 1:1:0:1." 1:1:0:1= I/O access : Camera control : Talk : Listen (refer to the section Security) Therefore, it denotes the user is granted privileges of I/O access, Camera control and
  • LevelOne FCS-4041 | User Manual - Page 54
    system's parameter setting. 7.2.17 Factory Default The Factory Default setting can be found under this path: System> Factory Default. Users can follow the instructions on this page to reset the IP Camera to factory default settings if needed. Set Default Click on the button to recall
  • LevelOne FCS-4041 | User Manual - Page 55
    7.2.18 Software Version The Software Version can be found under this path: System> Software Version. The current software version is displayed in the software version page. 7.2.19 Software Upgrade The Software Upgrade setting can be found under this path: System> Software Upgrade. NOTE: Make sure
  • LevelOne FCS-4041 | User Manual - Page 56
    list, select , and click on the button to uninstall the existing DC Viewer. Step 6: Open a new web browser, re-login the IP Camera, and then allow the automatic download of DC Viewer. 7.2.20 Maintenance The Maintenance setting can be found under this path: System> Maintenance.
  • LevelOne FCS-4041 | User Manual - Page 57
    > Video Format. Video Format Under Video Resolution section, the available video resolution formats are including MJPEG and H.264. Please refer to the User's Manual for more combination details. Click on to confirm the setting. Text Overlay Settings Users can select the items to display data
  • LevelOne FCS-4041 | User Manual - Page 58
    Video Rotate Type Users can change video display type if necessary. Selectable video rotate types include Normal, Flip, Mirror, 90 degree clockwise, 180 degree rotate and 90 degree counterclockwise. Differences among these types are illustrated as below. Suppose the displayed image of the IP Camera
  • LevelOne FCS-4041 | User Manual - Page 59
     Mirror If select , the image will be rotated horizontally.  90 Degree Counter-/clockwise Selecting will make the image 90° counter-/clockwise inversed.  180 Degree Rotate Selecting will make the image 180°inversed. Click on to confirm
  • LevelOne FCS-4041 | User Manual - Page 60
    7.3.2 Video Compression The Video Compression setting can be found under this path: Streaming> Video Compression. Users can select a proper MJPEG/H.264 compression mode on the video compression page, depending on the application. MJPEG Q (Quality) factor Higher value implies higher bit rates and
  • LevelOne FCS-4041 | User Manual - Page 61
    7.3.3 Video OCX Protocol The Video OCX Protocol setting can be found under this path: Streaming> Video OCX Protocol. In the Video OCX protocol setting page, users can select RTP over UDP, RTP over TCP, RTSP over HTTP or MJPEG over HTTP, for streaming media over the network. In the case of
  • LevelOne FCS-4041 | User Manual - Page 62
    7.3.4 Video OCX protocol setting options include:  RTP over UDP/ RTP over RTSP(TCP)/ RTSP over HTTP/ MJPEG over HTTP Select a mode according to your data delivery requirements.  Multicast Mode Enter all required data, including , , , <
  • LevelOne FCS-4041 | User Manual - Page 63
    7.3.6 Audio (Audio Mode and Bit Rate Settings) The Audio Mode setting can be found under this path: Streaming> Audio. In the Audio page, the Administrator can select one transmission mode and audio bit rate. Transmission Mode  Full-duplex (Talk and Listen simultaneously) In the Full-duplex mode,
  • LevelOne FCS-4041 | User Manual - Page 64
    Preset Programming can be found under this path: PTZ> Preset. Totally 256 Preset Points can be programmed for the IP Camera. Please refer to the instructions below to set a Preset Point. Preset Setting To setup a Preset Point, please first move the cursor to the live view pane. Then left click and
  • LevelOne FCS-4041 | User Manual - Page 65
    7.4.2 Cruise The Cruise Programming can be found under this path: PTZ> Cruise. The IP Camera supports up to eight Cruise Paths. Please follow the instructions below for Cruise Path setup. Cruise Setting To setup a Cruise Path, please first select a path number from the drop-down list. Then move the
  • LevelOne FCS-4041 | User Manual - Page 66
    in any direction. 7.4.3 Auto Pan The Auto Pan Programming can be found under this path: PTZ> Auto Pan. The IP Camera supports four Auto Pan Paths. Please refer to the instructions below to set an Auto Pan Path. Auto Pan Setting To setup an Auto Pan Path, please select a path number from
  • LevelOne FCS-4041 | User Manual - Page 67
    Sequence Line Programming can be found under this path: PTZ> Sequence. The IP Camera supports totally eight Sequence Lines; each Sequence Line consists of up to 64 Preset Points. Please refer to the instructions below to program a Sequence Line. NOTE: Before setting this function, users must pre
  • LevelOne FCS-4041 | User Manual - Page 68
    Sequence setting menu.  Sequence Line Please select the number of Sequence Line to be set from the drop-down list in the top of the Sequence setting menu.  Sequential Preset Points Setting Please setup each Preset Point of the programmed Sequence Line in order, assigning a Preset Point from the <
  • LevelOne FCS-4041 | User Manual - Page 69
    7.4.5 ] Home The Home Function can be found under this path: PTZ> Home. Users are able to set an operation mode to ensure constant monitoring. If the IP Camera idles for a period of time, the selected function will be activated automatically; this is the HOME function. The HOME function allows
  • LevelOne FCS-4041 | User Manual - Page 70
    7.4.6 Tilt Range The Tilt Range Setting can be found under this path: PTZ> Tilt Range. The IP Camera's tilt angle is adjustable from minimum -10° to maximum 190° Please enter the desired minimum and maximum tilt angle into the corresponding fields respectively. Click on the button to save the
  • LevelOne FCS-4041 | User Manual - Page 71
    Mode In this mode, it is iris that has premier priority in control of exposure. The value of iris is adjustable from F1.6 to F28. Manual Mode In this mode, users can change the Shutter speed (1/10000 to 1), Iris (F1.6 to F28), and Gain (1 to 15
  • LevelOne FCS-4041 | User Manual - Page 72
    or outdoor mode. ATW Mode (Auto Tracing White Balance) The Dome Camera takes out the signals in a screen in the range from 2500 K to 10000 K. Manual Mode In this mode, users can change the White Balance value manually via specifying R gain and B gain; the range of R/B gain is from 0 to 255. 72
  • LevelOne FCS-4041 | User Manual - Page 73
    7.4.9 Camera-Misc 1 (Miscellaneous Setups Menu 1) The Miscellaneous Setting Menu 1 can be found under this path: PTZ> Camera- Misc 1. In the Camera-Misc (Miscellaneous) Setups Menu 1, users can set various camera parameters including Backlight Compensation (BLC), Sharpness, Exposures Compensation (
  • LevelOne FCS-4041 | User Manual - Page 74
    NOTE: Flip setting is manual-controlled only. If a Preset Position or a point for other function (ex. Sequence) is set in the position that can only be reached through FLIP motion,
  • LevelOne FCS-4041 | User Manual - Page 75
    75
  • LevelOne FCS-4041 | User Manual - Page 76
    7.4.10 Camera-Misc 2 (Miscellaneous Setups Menu 2) The Miscellaneous Setting Menu 2 can be found under this path: PTZ> Camera- Misc 2. In the Camera-Misc (Miscellaneous) Setups Menu 2, users can setup various functions such Wide Dynamic Range (WDR), Auto Calibration, 2D Noise Reduction (2DNR), and
  • LevelOne FCS-4041 | User Manual - Page 77
    with another user name. Appendix A: Install UPnP Components Please follow the instructions below to install UPnP components. Step 1: Go to , click in the Add or Remove Programs page. Step 3: Select from the Components list in Components Wizard window of the Windows,
  • LevelOne FCS-4041 | User Manual - Page 78
    Filter Image Inverse Image Freeze Noise Reduction 2D 3D NETWORKING FCS-4041 1/2.8" Sony Progressive Scan CMOS Sensor 18X 1~8x variable 4.7~84.6 mm Auto / Manual Auto/ Indoor/ Outdoor/ ATW Auto / Manual 1/30 ~ 1/10k sec. Auto / Manual On / Off 360° endless -10° ~ 190° 0.5° ~ 90°/s 256 0.225° 5°~400
  • LevelOne FCS-4041 | User Manual - Page 79
    Interface Protocol Digital Alarm Input Digital Alarm Output Alarm Reaction Security Supported Web Browser GENERAL Environment Operating Temperature Dimension Weight Power Source Power Consumption Regulatory FCS-4041 H.264 Main Profile/ MJPEG Multiple Streams, H.264 + MJPEG/ H.264 + H.264 1080P
  • LevelOne FCS-4041 | User Manual - Page 80
    The procedure is as follows: Step 1: Click on the tab and select the option . Step 2: Click on button under section. Then click on the button under the section. A confirmation window will pop up. Click on
  • LevelOne FCS-4041 | User Manual - Page 81
    Step 6: Close the browser window, and restart a new one later for accessing the Camera. 81
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

1
FCS-4041
Day/Night H.264 2-Megapixel
PoE IP Dome Camera
User Manual
Ver1.0