 Upload Image by E-Mail Select this item and the Administrator can assign an e-mail address and configure various parameters. When the alarm is triggered, event images will be sent to the appointed e-mail address. NOTE: Make sure SMTP or FTP configuration has been completed. Please refer to section Mail and FTP for further details.  PTZ Function Assign a camera function: Preset, Sequence, Autopan or Cruise, and specify a Preset Point/Sequence Line/Autopan Path/Cruise Line for the camera to perform at an alarm occurrence. NOTE: Please refer to the sections through Preset to Sequence for details of Preset Point / Cruise Line / Autopan Path / Sequence Line setups. If the selected function is , it is required to enter its dwell time (1~ 256 sec.) in the corresponding field as shown below. When the alarm is triggered, the camera will go to the selected Preset Point and stay there for a user-defined period of time. As for other function modes, the camera will keep executing the specified function; to stop the performance, simply change the camera's status. NOTE: The dwell time is only adjustable when selecting Preset as the alarm action. When the dwell time is up, the Camera will go back to its trigger position and recheck alarm pin status.  Send HTTP notification Check this item, select the destination HTTP address, and specify the parameters for event notifications by triggered. When an alarm is triggered, the notification can be sent to the specified HTTP server. For instance, if the custom parameter is set as" action=1&group=2", and the HTTP server name is" http://192.168.0.1/admin.php", the notification will be sent to HTTP server as" http://192.168.0.1/admin.php? action=1&group=2" when alarm is triggered. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

41
Upload Image by E-Mail
Select this item and the Administrator can assign an e-mail address and
configure various parameters. When the alarm is triggered,
event
images will be sent to the appointed e-mail address.
NOTE:
Make sure SMTP or FTP configuration has been
completed. Please refer to section
Mail
and
FTP
for further
details.
PTZ Function
Assign a camera function: Preset, Sequence, Autopan or Cruise, and
specify a Preset Point/Sequence Line/Autopan Path/Cruise Line for the
camera to perform at an alarm occurrence.
NOTE:
Please refer to the sections through
Preset
to
Sequence
for details of Preset Point / Cruise Line / Autopan Path /
Sequence Line setups.
If the selected function is <Preset>, it is required to enter its dwell time
(1~ 256 sec.) in the corresponding field as shown below. When the
alarm is triggered, the camera will go to the selected Preset Point and
stay there for a user-defined period of time. As for other function modes,
the camera will keep executing the specified function; to stop the
performance, simply change the
camera’s status.
NOTE:
The dwell time is only adjustable when selecting Preset
as the alarm action. When the dwell time is up, the Camera will
go back to its trigger position and recheck alarm pin status.
Send HTTP notification
Check this item, select the destination HTTP address, and specify the
parameters for event notifications by <Alarm> triggered. When an alarm
is triggered, the notification can be sent to the specified HTTP server.