Lexmark lexmark J110 Service Manual - Page 209
Peristaltic Pump Removal, Tray 2 Covers Removal
![]() |
View all Lexmark lexmark J110 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 209 highlights
4085-001 Peristaltic Pump Removal 1. Remove the rear cover. Refer to "Rear Cover Removal" on page 4-3. 2. Remove the exit tray. Refer to "Exit Tray Removal" on page 4-5. 3. Remove the operator panel cover. Refer to "Operator Panel Cover/Operator Panel Removal" on page 4-5. 4. Remove right cover. Refer to "Right Cover/Power Switch Removal" on page 4-9. 5. Remove the power supply and tank. Note: When reinstalling the pump, be sure the gear alignment is correct. 6. Remove the two screws from the peristaltic pump and disconnect the pump from the gear. Tray 2 Covers Removal 1. Remove ten screws {A} from Tray 2 covers. 2. Remove the covers. Repair Information 4-49
![](/manual_guide/products/lexmark-j110-service-manual-1c3d013/209.png)
Repair Information
4-49
4085-001
Peristaltic Pump Removal
1.
Remove the rear cover. Refer to
“Rear Cover Removal” on
page 4-3
.
2.
Remove the exit tray. Refer to
“Exit Tray Removal” on page 4-5
.
3.
Remove the operator panel cover. Refer to
“Operator Panel
Cover/Operator Panel Removal” on page 4-5
.
4.
Remove right cover. Refer to
“Right Cover/Power Switch
Removal” on page 4-9
.
5.
Remove the power supply and tank.
Note:
When reinstalling the pump, be sure the gear alignment is
correct.
6.
Remove the two screws from the peristaltic pump and
disconnect the pump from the gear.
Tray 2 Covers Removal
1.
Remove ten screws {A} from Tray 2 covers.
2.
Remove the covers.