McAfee M-1250 Network Protection - Page 30
show failover-status, downloadstatus, software image
View all McAfee M-1250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
McAfee® Network Security Platform 6.0 Troubleshooting • If trust is not established, check the Sensor name and shared secret on both the Sensor and the Manager. • If the Sensor is not seeing attacks for a significant period of time, check status for Sensor health and established trust. Also, check your port configuration and cabling setup. show failover-status This command shows whether failover is enabled on the Sensor and the status of the peer Sensor. You can run the command from either Sensor. The output includes the fields Failover Enabled (must be YES) and Peer Status (must be UP). The former indicates whether the Sensor on which the command is issued has been configured to be part of a Failover Pair, and the latter shows the current state of the communication between the two Sensors. downloadstatus This command displays the status of various download/upload operations: signature, software image, and DoS profile downloads (from Manager to Sensor) and DoS profile and debug trace uploads (from Sensor to Manager). Lists the number of times you have performed the operation, status of your previous attempt to perform the operation (including-if the operation failed-the cause of failure), and the time the command was executed. 22