Meade TE923W-M User Manual - Page 40

Specifications

Page 40 highlights

Specifications Radio Frequency: 433 MHz RF Reception range: 100-328 feet (30 -100 m) Barometric Pressure Measuring Range: 14.75 inHg to 32.44 inHg (500 Hpa to 1100Hpa); (374.5 mmHg to 823.8 mmHg) Resolution: 0.003 inHg (0.1 Hpa, 0.08 mmHg) Accuracy: 0.015 inHg (5 Hpa; 0.38 mmHg) Sampling interval: 20 minutes Altitude Compensation Range: -657 ft to 16404 ft (-200m to +5000 m) Temperature (Indoor) Operating Range: 14.2°F to 140°F (-9.9°C to 60°C) Resolution: 0.2°F (0.1°C) Accuracy: 2°F (1°C) Sampling Interval: 10 seconds Temperature (remote) Range: -40°F to 176°F (-40°C to 80°C) Resolution: 0.2°F (0.1°C) Accuracy: 2°F (1°C) Transmitting Interval: around 47 seconds Humidity (Indoor) Operating Range: 0% to 99% Resolution: 1% Accuracy: 5% Sampling Interval: 10 seconds Humidity (Outdoor) Operating Range: 0% to 99% Resolution: 1% Accuracy: 5% Sampling Interval: 10 seconds Transmitting Interval: around 47 seconds Sunrise and Sunset Accuracy: 1min (latitude within 50°) Ultraviolet light Range: 0 UVI to 36UVI (15.4 MED/hour) Resolution : 0.1UVI (0.1 MED/h) Accuracy: 1UVI + 10% Transmitting Interval: 300 seconds Wind Direction Range: 0° to 360° Resolution: 22.5° Accuracy: 11.25° Starting Threshold: 3mph (4.8 Km/h) Transmitting interval: 33 seconds 40 TE923W IM1(ENG) HONEYWELL R.pmd 40 4/11/08, 5:28 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

40
Specifications
Radio Frequency
: 433 MHz
RF Reception range
: 100-328 feet (30 -100 m)
Barometric Pressure
Measuring Range: 14.75 inHg to 32.44 inHg (500 Hpa to 1100Hpa); (374.5 mmHg to 823.8
mmHg)
Resolution: 0.003 inHg (0.1 Hpa, 0.08 mmHg)
Accuracy: 0.015 inHg (5 Hpa; 0.38 mmHg)
Sampling interval: 20 minutes
Altitude Compensation Range: -657 ft to 16404 ft (-200m to +5000 m)
Temperature (Indoor)
Operating Range: 14.2
°
F to 140
°
F (-9.9
°
C to 60
°
C)
Resolution: 0.2
°
F (0.1
°
C)
Accuracy: 2
°
F (1
°
C)
Sampling Interval: 10 seconds
Temperature (remote)
Range: -40
°
F to 176
°
F (-40
°
C to 80
°
C)
Resolution: 0.2
°
F (0.1
°
C)
Accuracy: 2
°
F (1
°
C)
Transmitting Interval: around 47 seconds
Humidity (Indoor)
Operating Range: 0% to 99%
Resolution: 1%
Accuracy: 5%
Sampling Interval: 10 seconds
Humidity (Outdoor)
Operating Range: 0% to 99%
Resolution: 1%
Accuracy: 5%
Sampling Interval: 10 seconds
Transmitting Interval: around 47 seconds
Sunrise and Sunset
Accuracy: 1min (latitude within 50
°
)
Ultraviolet light
Range: 0 UVI to 36UVI (15.4 MED/hour)
Resolution : 0.1UVI (0.1 MED/h)
Accuracy: 1UVI + 10%
Transmitting Interval: 300 seconds
Wind Direction
Range: 0
°
to 360
°
Resolution: 22.5
°
Accuracy: 11.25
°
Starting Threshold: 3mph (4.8 Km/h)
Transmitting interval: 33 seconds