Operation - continued USING THE TIMER Turn the "ADVANCED OSD" to "ON" in the MAIN MENU to access the TIMER feature in OPTION3. Using an asterisk (*) alone in the DAY field means that the programmed schedule will run every day. Using the asterisk (*) and the name of the day means the programmed schedule will run only on that day. For example "*FRI" means that the schedule will run every Friday. A hyphen (-) in either the ON or OFF fields means that a time is not set. In order to use the Program Timer, at least either an ON or OFF time has to be set. A hyphen (-) in the INPUT or that the monitor will use the previously used display mode for that particular schedule. If a Repeat Timer sequence is selected in the FUNC. field, the Input field will show a hyphen (-). English Using special characters in the PROGRAM TIMER setting. To user the TIMER feature the first set the internal clock and the day of the week. The display can also be programmed to turn on or off at preset times, and which input the display will use at those times. The Program Timer which turns on or off the power at the day of the week, time and the input mode you want, or Repeat Timer which displays two input modes alternately can each be set also. In the "OPTION3" OSD menu, select "TIMER", then press the SET button. The "TIMER" screen appears. PRESENT TIME This sets the day of the week and present time. Example: Setting "WEDNESDAY", "22:05" In the "TIMER" menu, select "PRESENT TIME", then press the SET button. The "PRESENT TIME" screen appears. Set the items. Turn DAYLIGHT SAVING TIME on if daylight savings is observed. Select the day of the week. Set the clock using the 24-hour (HH/MM) format. To accept PRESENT TIME settings, highlight "SET"* in the PRESENT TIME OSD menu, then press the SET button to store the settings. * If you press the EXIT button instead of the SET button, Timer settings will not be accepted. Setting the PROGRAM TIMER using multiple inputs Set the INPUT field to "MULTI", then press the SET button. The "MULTI SCREEN SETTING" will appear on the screen. Use the p and q buttons to select "MULTI MODE", then use the + and - buttons to choose from "S BY S1, 2R, or 2L" and "PICTURE IN PICTURE MODE (BOTTOM LEFT~TOP LEFT)". Use the p and q buttons to select "MAIN"/"SUB" and "LEFT"/"RIGHT", then use the + and - buttons to choose from "VIDEO1 to "DVI". To set "REP.1~3" as the FUNC. Set the FUNC. field to "REP.1", "REP.2" or "REP.3", then press the SET button. The "REPEAT TIMER" menu will appear on the screen. Use the - and + buttons to choose from "SINGLE", "S BY S 1, 2R or 2L" and "PICTURE IN PICTURE MODE (BTM LFT to TOP LFT)", then adjust the items. PROGRAM TIMER The PROGRAM TIMER feature allows a series of scheduled operation times to be set. The display can be programmed to run on a particular day and time while using a desired input source. Under the Function setting (FUNC.) either a Screen Saver setting (ORBITER, INVERSE, WHITE) or a REPEAT TIMER program can be set for the monitor to use during the scheduled power-on time. NOTE: When a REPEAT TIMER program is selected as the Function setting, the Program Timer's Input option is not available. The input used will use the input that is programmed for the Repeat Timer program. Up to 10 individual PROGRAM TIMER schedules can be set. When schedules are set to perform functions at the same time, the schedule with the lower number has priority. For example schedule #1 has priority over schedule #10. When schedules overlap, each action is sequentially executed. English-24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

English
English-24
USING THE TIMER
²urn the “ADVANCED OSD” to “ON” in the MAIN MENU
to access the ²IMER feature in OP²ION3.
²o user the ²IMER feature the ±rst set the internal clock and
the day of the week. Te display can also be programmed to
turn on or o´
at preset times, and which input the display
will use at those times. Te Program ²imer which turns on
or o´
the power at the day of the week, time and the input
mode you want, or Repeat ²imer which displays two input
modes alternately can each be set also. In the “OP²ION3”
OSD menu, select “²IMER”, then press the SE² button. Te
“²IMER” screen appears.
PRESENT TIME
Tis sets the day of the week and present time. Example:
Setting “WEDNESDAY”, “22:05” In the “²IMER” menu,
select “PRESEN² ²IME”, then press the
SE² button.
Te “PRESEN² ²IME” screen appears. Set the items.
²urn DAYLIGH² SAVING ²IME on if daylight
savings is observed.
Select the day of the week.
Set the clock using the 24-hour (HH/MM) format.
²o accept PRESEN² ²IME settings, highlight “SE²”* in the
PRESEN² ²IME OSD menu, then press the
SE² button to
store the settings.
* If you press the EXIT button instead of the SET button,
Timer settings will not be accepted.
PROGRAM TIMER
Te PROGRAM ²IMER feature allows a series of scheduled
operation times to be set. Te display can be programmed to
run on a particular day and time while using a desired input
source. Under the Function setting (FUNC.) either a Screen
Saver setting (ORBI²ER, INVERSE, WHI²E) or a REPEA²
²IMER program can be set for the monitor to use during the
scheduled power-on time.
NO²E: When a REPEA² ²IMER program is selected as
the Function setting, the Program ²imer's Input option
is not available. Te input used will use the input that is
programmed for the Repeat ²imer program.
Up to 10 individual PROGRAM ²IMER schedules can be
set. When schedules are set to perform functions at the same
time, the schedule with the lower number has priority. For
example schedule #1 has priority over schedule #10. When
schedules overlap, each action is sequentially executed.
Using special characters in the PROGRAM TIMER
setting.
Using an asterisk (*) alone in the DAY ±eld means that the
programmed schedule will run every day.
Using the asterisk (*) and the name of the day means the
programmed schedule will run only on that day. For example
"*FRI" means that the schedule will run every Friday.
A hyphen (-) in either the ON or OFF ±elds means that a
time is not set. In order to use the Program ²imer, at least
either an ON or OFF time has to be set.
A hyphen (-) in the INPU² or that the monitor will use the
previously used display mode for that particular schedule.
If a Repeat ²imer sequence is selected in the FUNC. ±eld,
the Input ±eld will show a hyphen (-).
Setting the PROGRAM TIMER using multiple inputs
Set the INPU² ±eld to “MUL²I”, then press the SE² button.
Te “MUL²I SCREEN SE²²ING” will appear on the screen.
Use the
p
and
q
buttons to select “MUL²I MODE”, then
use the + and - buttons to choose from “S BY S1, 2R, or
2L” and “PIC²URE IN PIC²URE MODE (BO²²OM
LEF²~²OP LEF²)”.
Use the
p
and
q
buttons to select “MAIN”/“SUB” and
“LEF²”/“RIGH²”, then use the + and - buttons to choose
from “VIDEO1 to "DVI”.
To set “REP.1~3” as the FUNC.
Set the FUNC. ±eld to “REP.1”, “REP.2” or “REP.3”, then press
the SE² button. Te “REPEA² ²IMER” menu will appear on
the screen.
Use the - and + buttons to choose from “SINGLE”, “S BY S 1,
2R or 2L” and “PIC²URE IN PIC²URE MODE (B²M LF²
to ²OP LF²)”, then adjust the items.