RS-232C - continued 5) Read command Host computer sends the command without Data-code to monitor. After receiving this command, the monitor returns the command with Data-code of current status to host computer. When the Host computer checks the Power status of monitor, the status of monitor is powered-on. Command from computer 30 30 76 50 0D '0''0''v''P'[enter] Command from Monitor Detail of command Ask about the power status of monitor. 30 30 76 50 31 0D '0''0''v''P''1'[enter] Structure of the Read-command ASCII Function POWER ON POWER OFF INPUT VIDEO1 INPUT VIDEO2 INPUT S-VIDEO INPUT DVD/HD1 INPUT DVD/HD2 INPUT SCART3 INPUT VGA INPUT RGBHV INPUT DVI Picture Mode BRIGHT Picture Mode STANDARD Picture Mode CINEMA1 Picture Mode CINEMA2 Picture Mode DEFAULT vP vP vI vI vI vI vI vI vI vI vI vM vM vM vM vM Data 1 0 v1 v4 v3 v2 v5 v6 r2 r3 r1 p1 p2 p3 p4 p5 Monitor is powered-on. HEX Function Data 76h 50h 76h 50h 76h 49h 76h 49h 76h 49h 76h 49h 76h 49h 76h 49h 76h 49h 76h 49h 76h 49h 76h 4Dh 76h 4Dh 76h 4Dh 76h 4Dh 76h 4Dh 31h 30h 76h 31h 76h 34h 76h 33h 76h 32h 76h 35h 76h 36h 72h 32h 72h 33h 72h 31h 70h 31h 70h 32h 70h 33h 70h 34h 70h 35h English-29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

English-29
Structure of the Read-command
ASCII
HEX
Function
Data
Function
Data
POWER ON
vP
1
76h 50h
31h
POWER OFF
vP
0
76h 50h
30h
INPUT VIDEO1
vI
v1
76h 49h
76h 31h
INPUT VIDEO2
vI
v4
76h 49h
76h 34h
INPUT S-VIDEO
vI
v3
76h 49h
76h 33h
INPUT DVD/HD1
vI
v2
76h 49h
76h 32h
INPUT DVD/HD2
vI
v5
76h 49h
76h 35h
INPUT SCART3
vI
v6
76h 49h
76h 36h
INPUT VGA
vI
r2
76h 49h
72h 32h
INPUT RGBHV
vI
r3
76h 49h
72h 33h
INPUT DVI
vI
r1
76h 49h
72h 31h
Picture Mode BRIGHT
vM
p1
76h 4Dh
70h 31h
Picture Mode STANDARD
vM
p2
76h 4Dh
70h 32h
Picture Mode CINEMA1
vM
p3
76h 4Dh
70h 33h
Picture Mode CINEMA2
vM
p4
76h 4Dh
70h 34h
Picture Mode DEFAULT
vM
p5
76h 4Dh
70h 35h
5) Read command
Host computer sends the command without Data-code to monitor.
Aµer receiving this command, the monitor returns the command with Data-code
of current
status to host computer.
<ex> When the Host computer checks the Power status of monitor, the status of
monitor is powered-on.
Command from
computer
Command from
Monitor
Detail of command
30 30 76 50 0D
‘0’’0’’v’’P’[enter]
Ask about the power
status of monitor.
30 30 76 50 31 0D
‘0’’0’’v’'P'’1’[enter]
Monitor is powered-on.
RS-232C