Netgear RP614 RP614v4 Reference Manual - Page 53

Using Universal Plug and Play (UPnP), IP address range, Only this Computer, Apply

Page 53 highlights

RP614v4 Cable/DSL Router Reference Manual b. To allow access from a range of IP addresses on the Internet, select IP address range. Enter a beginning and ending IP address to define the allowed range. c. To allow access from a single IP address on the Internet, select Only this Computer. Enter the IP address that will be allowed access. 4. Specify the Port Number that will be used for accessing the management interface. Web browser access normally uses the standard HTTP service port 80. For greater security, change the remote management Web interface to a custom port by entering that number in the box provided. Choose a number between 1024 and 65535, but do not use the number of any common service port. The default is 8080, which is a common alternate for HTTP. 5. Click Apply to have your changes take effect. Note: When accessing your router from the Internet, you will type your router's WAN IP address into your browser's Address (in IE) or Location (in Netscape) box, followed by a colon (:) and the custom port number. For example, if your external address is 134.177.0.123 and you use port number 8080, you must enter http:// 134.177.0.123:8080 in your browser. Using Universal Plug and Play (UPnP) Universal Plug and Play (UPnP) helps devices, such as Internet appliances and computers, access the network and connect to other devices as needed. UPnP devices can automatically discover the services from other registered UPnP devices on the network. From the Main Menu of the browser interface, under Advanced, click on UPnP. Figure 4-11 Advanced Configuration of the Router v3.1, June 2008 4-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

RP614v4 Cable/DSL Router Reference Manual
Advanced Configuration of the Router
4-17
v3.1, June 2008
b.
To allow access from a range of IP addresses on the Internet, select
IP address range
.
Enter a beginning and ending IP address to define the allowed range.
c.
To allow access from a single IP address on the Internet, select
Only this Computer
.
Enter the IP address that will be allowed access.
4.
Specify the Port Number that will be used for accessing the management interface.
Web browser access normally uses the standard HTTP service port 80. For greater security,
change the remote management Web interface to a custom port by entering that number in the
box provided. Choose a number between 1024 and 65535, but do not use the number of any
common service port. The default is 8080, which is a common alternate for HTTP.
5.
Click
Apply
to have your changes take effect.
Using Universal Plug and Play (UPnP)
Universal Plug and Play (UPnP) helps devices, such as Internet appliances and computers, access
the network and connect to other devices as needed. UPnP devices can automatically discover the
services from other registered UPnP devices on the network.
From the Main Menu of the browser interface, under Advanced, click on UPnP.
Note:
When accessing your router from the Internet, you will type your router's WAN IP
address into your browser's Address (in IE) or Location (in Netscape) box,
followed by a colon (:) and the custom port number. For example, if your external
address is 134.177.0.123 and you use port number 8080, you must enter http://
134.177.0.123:8080 in your browser.
Figure 4-11