Nikon D7100 Product Manual - Page 281

f2: Assign Fn Button, Press

Page 281 highlights

f2: Assign Fn Button G button ➜ A Custom Settings menu Choose the role played by the Fn button, either by itself (Press) or when used in combination with the command dials (Press + command dials). ❚❚ Press Selecting Press displays the following options: Option Description q Preview Press the Fn button to preview depth of field (0 50). r FV lock Press the Fn button to lock flash value (built-in flash and compatible optional flash units only, 0 125, 305). Press again to cancel FV lock. B AE/AF lock Focus and exposure lock while the Fn button is pressed. C AE lock only Exposure locks while the Fn button is pressed. E AE lock (Hold) Exposure locks when the Fn button is pressed, and remains locked until the button is pressed a second time or the standby timer expires. F AF lock only Focus locks while the Fn button is pressed. A AF-ON Pressing the Fn button initiates autofocus. The shutter-release button can not be used to focus. s Flash off The flash will not fire in photos taken while the Fn button is pressed. t Bracketing burst If the Fn button is pressed while exposure, flash, or ADL bracketing is active in single frame or quiet shutter-release mode, all shots in the current bracketing program will be taken each time the shutter-release button is pressed. If white balance bracketing is active or continuous release mode (mode CH or CL) is selected, the camera will repeat the bracketing burst while the shutter-release button is held down. If image quality is set to JPEG fine, JPEG normal, or JPEG basic, "RAW" will be displayed in the control panel and an NEF (RAW) copy will be e + NEF (RAW) recorded with the next picture taken after the Fn button is pressed (to record NEF/RAW copies with a series of photographs, keep the shutter- release button pressed halfway between shots). To exit without recording an NEF (RAW) copy, press the Fn button again. L Matrix metering Matrix metering is activated while the Fn button is pressed. Center- M weighted Center-weighted metering is activated while the Fn button is pressed. metering N Spot metering Spot metering is activated while the Fn button is pressed. U 253

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382
  • 383
  • 384

253
U
Choose the role played by the
Fn
button, either by itself (
Press
)
or when used in combination with the command dials (
Press +
command dials
).
❚❚
Press
Selecting
Press
displays the following options:
f2: Assign Fn Button
G
button
A
Custom Settings menu
Option
Description
q
Preview
Press the
Fn
button to preview depth of field (
0
50).
r
FV lock
Press the
Fn
button to lock flash value (built-in flash and compatible
optional flash units only,
0
125, 305).
Press again to cancel FV lock.
B
AE/AF lock
Focus and exposure lock while the
Fn
button is pressed.
C
AE lock only
Exposure locks while the
Fn
button is pressed.
E
AE lock
(Hold)
Exposure locks when the
Fn
button is pressed, and remains locked until
the button is pressed a second time or the standby timer expires.
F
AF lock only
Focus locks while the
Fn
button is pressed.
A
AF-ON
Pressing the
Fn
button initiates autofocus.
The shutter-release button can
not be used to focus.
s
Flash off
The flash will not fire in photos taken while the
Fn
button is pressed.
t
Bracketing
burst
If the
Fn
button is pressed while exposure, flash, or ADL bracketing is active
in single frame or quiet shutter-release mode, all shots in the current
bracketing program will be taken each time the shutter-release button is
pressed.
If white balance bracketing is active or continuous release mode
(mode
C
H
or
C
L
) is selected, the camera will repeat the bracketing burst
while the shutter-release button is held down.
e
+ NEF (RAW)
If image quality is set to
JPEG fine
,
JPEG normal
, or
JPEG basic
, “RAW”
will be displayed in the control panel and an NEF (RAW) copy will be
recorded with the next picture taken after the
Fn
button is pressed (to
record NEF/RAW copies with a series of photographs, keep the shutter-
release button pressed halfway between shots). To exit without recording
an NEF (RAW) copy, press the
Fn
button again.
L
Matrix
metering
Matrix metering is activated while the
Fn
button is pressed.
M
Center-
weighted
metering
Center-weighted metering is activated while the
Fn
button is pressed.
N
Spot
metering
Spot metering is activated while the
Fn
button is pressed.