Oki OkiPOS406 OkiPOS406 Users Guide - Page 106
Change the setting of the DIP switches., Remove the 2 screws.
View all Oki OkiPOS406 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
The following is the procedure for changing the settings on DIP switch No. 3. 1. Turn off the printer and all components connected to it. 2. Remove the 2 screws. 3. Remove the serial interface board unit. 4. Change the setting of the DIP switches. 5. Replace the serial interface board unit. Then secure it with the screws. 6. Turn on the printer and all components connected to it. APPENDIX ON OFF No. 1 2 3 4 5 6 7 8 DIP-SW3 The factory settings of DIP switch are all on, except for switches 7 and 8. Switch 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 DIP-SW 3 Function ON OFF Baud Rate See table below Data Length Parity Check Parity Handshake Pin #6 (DSR) reset signal Pin #25 (INIT) reset signal 8 bits Disabled Odd DTR/DSR Valid Valid 7 bits Enabled Even XON/XOFF Invalid Invalid Baud Rate 4800BPS 9600BPS 19200BPS Switch 3-1 OFF ON ON - 103 - Switch 3-2 ON ON OFF