Oki OkiPOS406 OkiPOS406 Users Guide - Page 109

D-sub 25 Pin, D-sub 9 Pin option, X-On/X-Off Communication Mode

Page 109 highlights

Pin No. 25 Pin 9 Pin Signal name Direction Function Printer status 1. During the period from when the power is turned on (including resetting using the interface) to when the printer is ready to receive data. DIP SW 1-6 OFF ON BUSY BUSY 2. During the self printing. BUSY BUSY 3. When the cover is open. - BUSY 4. When the printer stops printing due to a paper-end. - BUSY 5. During macro executing standby status. - BUSY 6. When an error has occurred. 7. When the receive buffer becomes full. - BUSY BUSY BUSY 21~24 25 2) X-On/X-Off Communication Mode Always space, except during following conditions: • Period between reset and communication enabled • During self printing N/C Not used INIT IN • DIP Switch 3-8=OFF Status of this signal is not checked. • DIP Switch 3-8=ON This signal used for external reset. Printer is reset whenever signal is in space state with pulse width of 1mS or more. 13 1 D-sub 25 Pin 25 14 5 1 9 6 D-sub 9 Pin (option) APPENDIX - 106 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113

– 106 –
APPENDIX
Pin No.
Signal name
Direction
Function
25 Pin
9 Pin
2) X-On/X-Off Communication Mode
Always space, except during following conditions:
• Period between reset and communication enabled
• During self printing
21~24
N/C
Not used
25
INIT
IN
• DIP Switch 3-8=OFF
Status of this signal is not checked.
• DIP Switch 3-8=ON
This signal used for external reset. Printer is reset whenever signal
is in space state with pulse width of 1mS or more.
Printer status
DIP SW 1-6
OFF
ON
1. During the period from when the
power is turned on (including reset-
ting using the interface) to when the
printer is ready to receive data.
2. During the self printing.
3. When the cover is open.
4.
When the printer stops printing due to
a paper-end.
5. During macro executing standby
status.
6. When an error has occurred.
7. When the receive buffer becomes
full.
BUSY
BUSY
BUSY
BUSY
-
BUSY
-
BUSY
-
BUSY
-
BUSY
BUSY
BUSY
13
25
1
14
5
9
1
6
D-sub 25 Pin
D-sub 9 Pin (option)