Oregon Scientific WMR100N User Manual - Page 10
Temperature And Humidity, Temperature And Humidity Trend, Comfort Level, Wind Direction / Speed - weather station set
View all Oregon Scientific WMR100N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
EN TEMPERATURE AND HUMIDITY The weather station displays indoor and outdoor readings for: 1. Current, minimum and maximum temperatures and relative humidity. 2. Comfort level indicator and trend line. 3. Heat index, wind chill and dew point level. The weather station can connect up to 10 remote sensors. NOTE Channel 1 is dedicated for outdoor temperature and humidity. shows which remote sensor's data you are viewing. appears when indoor data is displayed. The timestamp records the date and time when storing the temperature and humidity readings in memory. To select the temperature measurement unit: Press UNIT (at the bottom of the base station) to select °C / °F. NOTE The unit of all temperature related displays will be changed simultaneously. To view temperature (Current temperature, Heat Index and Wind Chill): 1. Press SELECT to navigate to the Temperature Area. will show next to the Area. 2. Rotate the dial left or right to select the channel. 3. Press MODE repeatedly to toggle between the different displays. 4. Press MEMORY / ON / OFF to select MAX / MIN display. To clear the memories and timestamp for the temperature, heat index, wind chill, humidity and dew point readings: In the Temperature or Humidity Area, press and hold MEMORY / ON / OFF to clear the readings. To change the high / low temperature, heat index, wind chill, humidity and dew point alarms: 1. In the Temperature or Humidity Area, press ALARM repeatedly to toggle between high / low alarms for temperature, heat index, wind chill, humidity and dew point readings. 2. Press and hold ALARM to enter the alarm setting. 3. Rotate the dial left or right to set the desired values. 4. Press ALARM to confirm the setting. To activate / deactivate the high / low temperature, heat index, wind chill, humidity and dew point alarms: 1. In the Temperature or Humidity Area, press ALARM repeatedly to select the desired alarm. 2. Press MEMORY / ON / OFF to activate or deactivate the alarm. NOTE The dew point advises at what temperature condensation will form. The wind chill factor is based on the combined effects of temperature and wind speed. TEMPERATURE AND HUMIDITY TREND The trend lines are shown next to the temperature and humidity readings. The trend is shown as follows: RISING STEADY FALLING NOTE To view wind chill, ensure channel 1 is selected. To view humidity (Humidity, Dew point): 1. Press SELECT to navigate to the Humidity Area. will show next to the Area. 2. Rotate the dial left or right to select the channel. 3. Press MODE repeatedly to toggle between the different displays. 4. Press MEMORY / ON / OFF to select MAX / MIN display. Data required Current Temperature Heat Index Wind Chill Humidity Dew Point Area located Temperature Humidity Channels supported Indoor and 1-10 outdoor 1 only Indoor and 1-10 outdoor Type of memory MAX MIN MAX MIN MAX MIN MAX MIN The timestamp is displayed accordingly in the Clock Area. COMFORT LEVEL The Comfort Zone icon indicates how comfortable the climate is based on current temperature and humidity measurements: COMFORTABLE NEUTRAL UNCOMFORTABLE WIND DIRECTION / SPEED The base station provides wind speed and wind direction information. To read the wind direction find the compass point the is pointing to. The timestamp records the date and time when storing the wind speed readings. 10