Oregon Scientific WMR100N User Manual - Page 14

Outdoor Temperature / Humidity Unit

Page 14 highlights

EN INDOOR RELATIVE HUMIDITY Displayed range 2% to 98% Operating range 25% to 90% Resolution 1% Accuracy 25% - 40%: +/- 7% 40% - 80%: +/- 5% 80% - 90%: +/- 7% Comfort 40% to 70% Memory Current, Min and Max Alarm Hi / Lo RADIO-CONTROLLED / ATOMIC CLOCK Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM or24hr Calendar DD/MM or MM/DD Weekday in 5 (E, G, F, I, S) languages Battery 4 x UM-3 (AA) 1.5V batteries AC adapter 6V REMOTE WIND SENSOR UNIT Dimensions 178 x 76 x 214 mm (L x W x H) (7 x 3 x 8.4 inches) Weight 100 g (3.53 oz) without battery Wind speed unit m/s, kph, mph, knots Speed accuracy 2 m/s ~ 10 m/s (+/- 3 m/s) 10 m/s ~ 56 m/s (+/- 10%) Direction accuracy 16 positions Transmission of Approx. every 14 seconds wind speed signal Memory Max speed gust Battery 2 x UM-3 (AA) 1.5V batteries OUTDOOR TEMPERATURE / HUMIDITY UNIT • RELATIVE TEMPERATURE Dimensions 115 x 87 x 118 mm (L x W x H) (4.5 x 3.4 x 4.6 inches) Weight 130 g (4.59 oz) without battery Temp. unit °C / °F Displayed range -50°C to 70°C (-58°F to 158°F) Operating range -30°C to 60°C (-4°F to 140°F) Accuracy -20°C - 0°C: +/- 2°C (+/- 4.0°F) 0°C - 40°C: +/- 1°C (+/- 2.0°F) 40°C - 50°C: +/- 2°C (+/- 4.0°F) 50°C - 60°C: +/- 3°C (+/- 6.0°F) Comfort 20°C to 25°C (68°F to 77°F) Memory Current, Min and Max temp. Dew Point w/ Max and Min Wind chill temp. and min • RELATIVE HUMIDITY Displayed range 2% to 98% Operating range 25% to 90% Resolution 1% Accuracy 25% - 40%: +/- 7% 40% - 80%: +/- 5% 80% - 90%: +/- 7% Comfort 40% to 70% Memory Current, Min and Max Battery 2 x UM-4 (AAA) 1.5V batteries RF TRANSMISSION RF frequency 433MHz Range Up to 100 meters (328 feet) with no obstructions Transmission Approx. every 60 seconds No. of Channel 1 for Wind/ Rain/ UV and 10 for Temp. / Humidity REMOTE RAIN GAUGE Dimensions 114 x 114 x 145 mm (L x W x H) 4.5 x 4.5 x 5.7 inches Weight Rainfall unit Range 241 g (8.50 oz lbs) without battery Mm/hr and in/hr 0 mm/hr - 9999 mm/hr Resolution Accuracy Memory Battery 1 mm/hr < 15 mm/hr: +/- 1 mm 15 mm to 9999 mm: +/- 7% Past 24hrs, hourly and accumulated from last memory reset 2 x UM-3 (AA) 1.5V PRECAUTIONS • Do not subject the unit to excessive force, shock, dust, temperature or humidity. • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. • Do not tamper with the unit's internal components. This invalidates the warranty. • Only use fresh batteries. Do not mix new and old batteries. • Images shown in this manual may differ from the 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

14
EN
INDOOR RELATIVE HUMIDITY
Displayed range
2% to 98%
Operating range
25% to 90%
Resolution
1%
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort
40% to 70%
Memory
Current, Min and Max
Alarm
Hi / Lo
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization
Auto or disabled
Clock display
HH:MM:SS
Hour format
12hr AM/PM or24hr
Calendar
DD/MM or MM/DD
Weekday in 5
(E, G, F, I, S)
languages
Battery
4 x UM-3 (AA) 1.5V batteries
AC adapter 6V
REMOTE WIND SENSOR UNIT
Dimensions
178 x 76 x 214 mm
(L x W x H)
(7 x 3 x 8.4 inches)
Weight
100 g (3.53 oz) without battery
Wind speed unit
m/s, kph, mph, knots
Speed accuracy
2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy
16 positions
Transmission of
Approx. every 14 seconds
wind speed signal
Memory
Max speed gust
Battery
2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
RELATIVE TEMPERATURE
Dimensions
115 x 87 x 118 mm
(L x W x H)
(4.5 x 3.4 x 4.6 inches)
Weight
130 g (4.59 oz) without battery
Temp. unit
°C / °F
Displayed range
-50°C to 70°C (-58°F to 158°F)
Operating range
-30°C to 60°C (-4°F to 140°F)
Accuracy
-20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
50°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort
20°C to 25°C (68°F to 77°F)
Memory
Current, Min and Max temp.
Dew Point w/ Max and Min
Wind chill temp. and min
RELATIVE HUMIDITY
Displayed range
2% to 98%
Operating range
25% to 90%
Resolution
1%
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort
40% to 70%
Memory
Current, Min and Max
Battery
2 x UM-4 (AAA) 1.5V batteries
RF TRANSMISSION
RF frequency
433MHz
Range
Up to 100 meters (328 feet) with
no obstructions
Transmission
Approx. every 60 seconds
No. of Channel
1 for Wind/ Rain/ UV and 10 for
Temp. / Humidity
REMOTE RAIN GAUGE
Dimensions
114 x 114 x 145 mm
(L x W x H)
4.5 x 4.5 x 5.7 inches
Weight
241 g (8.50 oz lbs) without
battery
Rainfall unit
Mm/hr and in/hr
Range
0 mm/hr – 9999 mm/hr
Resolution
1 mm/hr
Accuracy
< 15 mm/hr: +/- 1 mm
15 mm to 9999 mm: +/- 7%
Memory
Past 24hrs, hourly and
accumulated
from last memory reset
Battery
2 x UM-3 (AA) 1.5V
PRECAUTIONS
Do not subject the unit to excessive force, shock,
dust, temperature or humidity.
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the