Oregon Scientific WMR100N User Manual - Page 11

Uvi / Barometer / Rainfall, Uv Index - weather station

Page 11 highlights

EN To select the wind speed unit: Press UNIT (at the bottom of the base station) to switch between: • Metres per second (m / s) • Kilometers per hour (kph) • Miles per hour (mph) • Knots (knots) The wind level is shown by a series of icons: ICON LEVEL DESCRIPTION N/A 88 km/h) To view the UV / Barometer / Rainfall readings: 1. Press SELECT to navigate to the UV / Barometer / Rainfall Area. will show next to the Area. 2. Press MODE to toggle between UVI / Barometer / Rainfall readings. The corresponding icon will appear: UVI BAROMETER RAINFALL To display the AVERAGE and GUST wind: 1. Press SELECT to navigate to the Wind Speed and Wind Direction Area. will show next to the Area. 2. Press MODE to toggle between AVERAGE and GUST wind readings. To display the maximum speed and direction for gust wind: In the Wind Speed and Wind Direction Area, press MEMORY / ON / OFF to toggle between wind speed / MAX GUST wind readings. The timestamp is displayed accordingly in the Clock Area. To clear the memories and timestamp for the wind readings: In the Wind Speed and Wind Direction Area, press and hold MEMORY / ON / OFF to clear the readings. To change the high gust wind speed alarm: 1. In the Wind Speed and Wind Direction Area, press and hold ALARM to enter the high gust wind alarm setting. 2. Rotate the dial left or right to set the desired values. 3. Press ALARM to confirm the settings. To activate / deactivate the high gust wind speed alarm: 1. In the Wind Speed and Wind Direction Area, press ALARM repeatedly to select the desired alarm. 2. Press MEMORY / ON / OFF to activate or deactivate the alarm. 3. Rotate the dial left or right to view the historical data for the selected area. The corresponding historical readings are showing. NOTE The number shown in the HR icon indicates how long ago each measurement was taken (e.g. 2 hours ago, 3 hours ago, etc.). To select the measurement unit for the barometer or rainfall readings: In the UV / Barometer / Rainfall Area, press UNIT (at the bottom of the base station) to switch between: • Barometer: Millimeters of mercury (mmHg), inches of mercury (inHg), millibars per hectopascal (mb / hpa). • Rainfall: Millimeters (mm), inches (in), inches per hour (in / hr) or millimeters per hour (mm / hr). UV INDEX The UV index levels are as follows: UV INDEX 0-2 3-5 6-7 8-10 11 and above DANGER LEVEL Low Moderate High Very high Extremely high ICON UVI / BAROMETER / RAINFALL The weather station works with one UV sensor and one rain gauge. The station is capable of storing and displaying the hourly history data for the last 10 hours To change the high UV alarm: 1. In the UV / Barometer / Rainfall Area and UVI reading display. Press and hold ALARM to enter the high UV alarm setting. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

11
EN
To select the wind speed unit:
Press
UNIT
(at the bottom of the base station) to switch
between:
Metres per second (
m / s
)
Kilometers per hour (
kph
)
Miles per hour (
mph
)
Knots (
knots
)
The wind level is shown by a series of icons:
ICON
LEVEL
DESCRIPTION
N/A
<2 mph (<4km/h)
Light
2-8 mph (3~13 km/h)
Moderate
9-25 mph (~14-41 km/h)
Strong
26-54 mph (~42-87 km/h)
Storm
>55 mph (>88 km/h)
To display the AVERAGE and GUST wind:
1. Press
SELECT
to navigate to the Wind Speed and
Wind Direction Area.
will show next to the Area.
2. Press
MODE
to toggle between AVERAGE and GUST
wind readings.
To display the maximum speed and direction for
gust wind:
In the Wind Speed and Wind Direction Area, press
MEMORY /
ON / OFF
to toggle between wind speed
/ MAX GUST wind readings. The timestamp is displayed
accordingly in the Clock Area.
To clear the memories and timestamp for the wind
readings:
In the Wind Speed and Wind Direction Area, press and
hold
MEMORY /
ON / OFF
to clear the readings.
To change the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press
and hold
ALARM
to enter the high gust wind alarm
setting.
2.
Rotate the dial left or right to set the desired values.
3. Press
ALARM
to confirm the settings.
To activate / deactivate the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press
ALARM
repeatedly to select the desired alarm.
2. Press
MEMORY /
ON / OFF
to activate or
deactivate the alarm.
UVI / BAROMETER / RAINFALL
The weather station works with one UV sensor and
one rain gauge. The station is capable of storing and
displaying the hourly history data for the last 10 hours
of UV index, and 24 hours of rainfall and barometric
pressure readings.
UVI
BAROMETER
RAINFALL
The bar chart display shows the current and historical
data for the UV index, barometric pressure and rainfall
readings.
To view the UV / Barometer / Rainfall readings:
1. Press
SELECT
to navigate to the UV / Barometer /
Rainfall Area.
will show next to the Area.
2. Press
MODE
to toggle between UVI / Barometer /
Rainfall readings. The corresponding icon will appear:
UVI
BAROMETER
RAINFALL
3.
Rotate the dial left or right to view the historical data
for the selected area. The corresponding historical
readings are showing.
NOTE
The number shown in the HR icon indicates how
long ago each measurement was taken (e.g. 2 hours ago,
3 hours ago, etc.).
To select the measurement unit for the barometer or
rainfall readings:
In the UV / Barometer / Rainfall Area, press
UNIT
(at the
bottom of the base station) to switch between:
Barometer: Millimeters of mercury (
mmHg
), inches
of mercury (
inHg
), millibars per hectopascal (
mb /
hpa
).
Rainfall: Millimeters (
mm
), inches (
in
), inches per
hour (
in / hr
) or millimeters per hour (
mm / hr
).
UV INDEX
The UV index levels are as follows:
UV INDEX
DANGER LEVEL
ICON
0-2
Low
3-5
Moderate
6-7
High
8-10
Very high
11 and above
Extremely high
To change the high UV alarm:
1.
In the UV / Barometer / Rainfall Area and UVI reading
display. Press and hold
ALARM
to enter the high UV
alarm setting.