Panasonic KX-TGP500B04 Administration Guide - Page 165

Dial_tone_timing, Busy_tone_frq, Busy_tone_timing

Page 165 highlights

4.5.2 Tone Settings Value Range Default Value Web User Interface Reference 0, 200-1000 (0: No tone) Note • If the value for this setting is "350,440", the unit will use a mixed signal of a 350 Hz tone and a 440 Hz tone. 350,440 Tone Frequencies (Page 115) DIAL_TONE_TIMING Value Format Description Value Range Default Value Web User Interface Reference Comma-separated Integer Specifies the pattern, in milliseconds, of dial tones using 4 whole numbers (on 1, off 1, on 2, off 2) separated by commas. 0-5000 (0: Infinite time) Note • The unit will play the tone for the duration of the first value, stop it for the duration of the second value, play it for the duration of the third value, and then stop it for the duration of the last value. The whole sequence will then repeat. For example, if the value for this setting is "100,100,0,0", the unit will play the tone for 100 ms, stop it for 100 ms, and then play it continuously. 0,0,0,0 (The unit plays the dial tone continuously.) Tone Timings (Page 115) BUSY_TONE_FRQ Value Format Description Value Range Default Value Web User Interface Reference Comma-separated Integer Specifies the dual-tone frequencies, in hertz, of busy tones using 2 whole numbers separated by a comma. 0, 200-1000 (0: No tone) 480,620 Tone Frequencies (Page 116) BUSY_TONE_TIMING Value Format Description Value Range Default Value Comma-separated Integer Specifies the pattern, in milliseconds, of busy tones using 4 whole numbers (on 1, off 1, on 2, off 2) separated by commas. 0-5000 (0: Infinite time) 500,500,500,500 Document Version 2010-08 Administrator Guide 165

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256

Value Range
0, 200–1000 (0: No tone)
Note
If the value for this setting is "350,440", the unit will use a mixed
signal of a 350 Hz tone and a 440 Hz tone.
Default Value
350,440
Web User Interface Reference
Tone Frequencies (Page 115)
DIAL_TONE_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of dial tones using 4 whole
numbers (on 1, off 1, on 2, off 2) separated by commas.
Value Range
0–5000 (0: Infinite time)
Note
The unit will play the tone for the duration of the first value, stop
it for the duration of the second value, play it for the duration of
the third value, and then stop it for the duration of the last value.
The whole sequence will then repeat. For example, if the value
for this setting is "100,100,0,0", the unit will play the tone for 100
ms, stop it for 100 ms, and then play it continuously.
Default Value
0,0,0,0 (The unit plays the dial tone continuously.)
Web User Interface Reference
Tone Timings (Page 115)
BUSY_TONE_FRQ
Value Format
Comma-separated Integer
Description
Specifies the dual-tone frequencies, in hertz, of busy tones using 2
whole numbers separated by a comma.
Value Range
0, 200–1000 (0: No tone)
Default Value
480,620
Web User Interface Reference
Tone Frequencies (Page 116)
BUSY_TONE_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of busy tones using 4 whole
numbers (on 1, off 1, on 2, off 2) separated by commas.
Value Range
0–5000 (0: Infinite time)
Default Value
500,500,500,500
Document Version
2010-08
Administrator Guide
165
4.5.2 Tone Settings