Panasonic PT AE700U Lcd Projector - Page 25
Care And Maintenance, When The Temp Indicator And The Lamp Indicator Are Illuminated - shut down
UPC - 410000150467
View all Panasonic PT AE700U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
When the TEMP indicator and the LAMP indicator are illuminated There are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem. LAMP indicator TEMP indicator TEMP indicator Indicator display Illuminated (red) (Lamp unit on) Flashing (red) (Lamp unit off) The surrounding temperature or The surrounding temperature or the temperature inside the the temperature inside the projector has become unusually projector has become Problem high. dangerously high, causing the lamp unit to automatically shut off. Possible cause B The ventilation holes may be covered. B The ambient temperature in the place of use may be too high. B The air filter may be blocked. B Uncover the ventilation holes. B Set up the projector in a place where the temperature is between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is between 20% and 80% (with no condensation). [If you set the Remedy "FAN CONTROL" to "HIGH" (page 47), set up the projector in a place where the temperature is between 0 °C (32 °F) and 35 °C (95 °F) and the humidity is between 20% and 80% (with no condensation).] B Turn off the MAIN POWER switch by following the procedure on page 26, and then clean the air filter (refer to page 50). 48-ENGLISH LAMP indicator Indicator display Illuminated (red) It is nearly time to Problem replace the lamp unit. Flashing (red) An abnormality has been detected in the lamp circuit. B Does "REPLACE Possible cause LAMP" appear on the screen after the projector is turned on? B The power may have been turned on straight away after it was turned off. B There may be an abnormality in the lamp circuit. B This occurs when B Wait for a while B Turn off the MAIN the operation time until the lamp unit POWER switch by for the lamp unit is cools down before following the nearing 2 700 turning the power procedure given hours (when back on again. on page 26, and "LAMP POWER" then contact an has been set to Authorized Remedy "HIGH" and when "DYNAMIC IRIS" Service Center. has been set to "ON"). Ask your dealer or an Authorized Service Center to replace the lamp unit. NOTE: B Be sure to turn off the MAIN POWER switch by following the procedure given in "Turning off the power" on page 26 before carrying out any of the procedures in the "Remedy" column. B If the power turns off after the TEMP indicator has illuminated, it means an abnormality has occurred. Please contact an Authorized Service Center so that the necessary repairs can be made. ENGLISH-49 Care and maintenance