Panasonic WJND200 WJND200 User Guide - Page 55

Settings relating to network [Comm], Basic settings for a network [Basic Setup], Setup items

Page 55 highlights

Settings relating to network [Comm] Perform the settings for a network connection such as settings of the IP address and gateway address. Basic settings for a network [Basic Setup] Basic network settings can be configured with this menu. Screenshot 1 Click the [Comm] button in the "Setup" panel and then click the "Basic Setup" tab. The "Basic Setup" page will be displayed. Step 1 Perform the settings for each item. Refer to the following for further information about the settings for each item. Step 2 Click the [SET] button after completing the settings. Setup items NW Link down detection Select "ON" or "OFF" to enable or disable the network line disconnection detection for the network port on the rear of the unit. ON: Detects if the disconnection of the network line connected to the network port occurs. OFF: Does not detect the network line disconnection. NW Bandwidth Control Select a rate for transmission from the following. Unlimited/32 kbps/64 kbps/128 kbps/256 kbps/ 512 kbps/1 024 kbps/2 Mbps/5 Mbps/10 Mbps Important: The bandwidth will not be controlled when live images are transmitted in MPEG-4 format. HTTP Port Number Specify the HTTP port number to be used to send images from the unit. A number from 1 - 65535 is available.It is unnecessary to change it for normal use. Notes: • Depending on the network settings of the LAN or Internet service provider, network communication may not be established if the http port number has been changed. In this case, refer to the administrator of the network. • The following port numbers and the port numbers used for the FTP port and for the site alarm setting are unavailable for the HTTP port number. 20, 21, 23, 25, 42, 53, 67, 68, 69, 79, 105, 110, 123, 161, 162, 546, 547, 995, 10001, 10002, 10003, 10004, 10005, 10006, 10007 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

55
Settings relating to network [Comm]
Perform the settings for a network connection such as settings of the IP address and gateway address.
Basic settings for a network [Basic Setup]
Basic network settings can be configured with this menu.
Screenshot 1
Click the [Comm] button in the "Setup" panel and then
click the "Basic Setup" tab. The "Basic Setup" page will
be displayed.
Step 1
Perform the settings for each item.
Refer to the following for further information about the
settings for each item.
Step 2
Click the [SET] button after completing the settings.
NW Link down detection
Select "ON" or "OFF" to enable or disable the network
line disconnection detection for the network port on the
rear of the unit.
ON:
Detects if the disconnection of the network line
connected to the network port occurs.
OFF:
Does not detect the network line disconnection.
NW Bandwidth Control
Select a rate for transmission from the following.
Unlimited/32 kbps/64 kbps/128 kbps/256 kbps/
512 kbps/1 024 kbps/2 Mbps/5 Mbps/10 Mbps
Important:
The bandwidth will not be controlled when live
images are transmitted in MPEG-4 format.
HTTP Port Number
Specify the HTTP port number to be used to send
images from the unit. A number from 1 - 65535 is avail-
able.It is unnecessary to change it for normal use.
Notes:
Depending on the network settings of the LAN or
Internet service provider, network communication
may not be established if the http port number has
been changed. In this case, refer to the administra-
tor of the network.
The following port numbers and the port numbers
used for the FTP port and for the site alarm setting
are unavailable for the HTTP port number.
20, 21, 23, 25, 42, 53, 67, 68, 69, 79, 105, 110, 123,
161, 162, 546, 547, 995, 10001, 10002, 10003,
10004, 10005, 10006, 10007
Setup items