Panasonic WV-NW484S Network Camera - Page 31
Alarm In/Out Ratings, Pin Arrangement of 4-pin Alarm Cable accessory, Open or 4 V DC to 5 V
![]() |
UPC - 791871505403
View all Panasonic WV-NW484S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Alarm In/Out Ratings Terminal Name ALARM IN ON OFF ALARM OUT OPEN CLOSE AUX OUT OPEN CLOSE DAY/NIGHT IN ON (black and white) OFF (color) Rating 5 V DC pull-up built in Short-circuit with GND (necessary drive current is 1 mA or greater) Open or 4 V DC to 5 V Open collector output (internal pullup/maximum drive current 50 mA), latch/pulse 4 V DC to 5 V 1 V DC maximum Open collector output (internal pullup/maximum drive current 50 mA) Open or 4 V DC to 5 V 1 V DC maximum DC 5 V pull-up built in Short-circuit with GND (necessary drive current is 1 mA or greater) Open or 4VDC to 5V Remarks Latch/pulse setting selectable Terminal shared with ALARM OUT. Can be selected in settings (Default setting: ALARM OUT) Not.e...• Check the Operating Instructions (provided) to see if the ratings of sensors and other external devices are compatible with the camera ratings...Pin Arrangement of 4-pin Alarm Cable (accessory) 1 Black 2 Gray 3 Red 4 Green GND AUX OUT ALARM OUT or DAY/NIGHT IN ALARM IN 31
![](/manual_guide/products/panasonic-wvnw484s-network-camera-1b69f87/31.png)