5. Step Selection When the machine in standby or pause state, every time when pressing "STEP" button, the selected STEP symbol will be blink in order on the screen, thus the power (wattage), temperature and timing corresponding to the selected STEP can be set. You can also press the "RUN/PAUSE" key to RUN the program backwards from the selected step. Program I can choose any step from all the step of S - L, program II can choose any step from B1 to B3, program III can choose any step from all steps of S - B3. 6. Setting of power, temperature and timing When the machine in standby or suspended state, press "STEP" to select a step and reset the setting of power, temperature and timing corresponding to this step. Every time to press "SET" button, the setting will follow below order to cycle, the icon corresponding the selected symbol will blink, and then press (+) and (-) button to reset the value. Temperature Timing Power 7. Restore default factory settings In the standby or pause state, keep press "PROG" button for 5 seconds to restore the factory settings, the previous set procedures and settings will be eliminated from the machine. Note: in general, if the settings are wrong and memory or program is out of order, you can pause at rst and then restore the factory settings. 8. Adjustment of temperature deviation (temperature compensation function) In standby or pause state, keep press "°C/°F" button for 5 seconds to enter the function of temperature deviation adjustment. Pressing (+) and (-) button to modify the temperature deviation. After determining the value, press the SET button to save the settings. The range of this deviation adjustment is within ±10°C. Note: 1. This adjustment function is required in winter when the external environment temperature is too low, the heat loss is too fast, or the water is boiling due to the high altitude, and the temperature cannot reach 100°C/212°F to enter the later program. 2. If it is found that there is a big error between the display temperature and the measured temperature during the course of using, the value can be adjusted and corrected through this function. 9. Conversion between Celsius and Fahrenheit °F Press "°C/°F" button at any time after starting up to convert the display of °C and Fahrenheit °F. 10. Power o protection function If there is an unexpected power failure after starting up, the machine will automatically remember the breakpoint. When the power is switched on again, the breakpoint will be automatically found by the machine. Press the "RUN/PAUSE" button to restart this step and continue to RUN the next step as previous settings. 12 www.NutrichefKitchen.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

www.NutrichefKitchen.com
12
5. Step Selection
When the machine in standby or pause state, every time when pressing "
STEP
" button, the selected
STEP symbol will be blink in order on the screen, thus the power (wattage), temperature and timing
corresponding to the selected STEP can be set. You can also press the "
RUN/PAUSE
" key to RUN the
program backwards from the selected step. Program I can choose any step from all the step of S - L,
program II can choose any step from B1 to B3, program III can choose any step from all steps of S - B3.
6. Setting of power, temperature and timing
When the machine in standby or suspended state, press "
STEP
" to select a step and reset the setting of
power, temperature and timing corresponding to this step.
Every time to press "
SET
" button, the setting will follow below order to cycle, the icon corresponding
the selected symbol will blink, and then press (+) and (-) button to reset the value.
7. Restore default factory settings
In the standby or pause state, keep press "
PROG
" button for 5 seconds to restore the factory settings,
the previous set procedures and settings will be eliminated from the machine.
Note:
in general, if the settings are wrong and memory or program is out of order, you can pause at
first and then restore the factory settings.
8. Adjustment of temperature deviation (temperature compensation function)
In standby or pause state, keep press "
°C/°F
" button for 5 seconds to enter the function of temperature
deviation adjustment. Pressing (+) and (-) button to modify the temperature deviation.
After determining the value, press the SET button to save the settings.
The range of this deviation adjustment is within ±10°C.
Note:
1. This adjustment function is required in winter when the external environment temperature is too low,
the heat loss is too fast, or the water is boiling due to the high altitude, and the temperature cannot
reach 100°C/212°F
to enter the later program.
2. If it is found that there is a big error between the display temperature and the measured temperature
during the course of using, the value can be adjusted and corrected through this function.
9. Conversion between Celsius and Fahrenheit °F
Press "
°C/°F
" button at any time after starting up to convert the display of °C and Fahrenheit °F.
10. Power off protection function
If there is an unexpected power failure after starting up, the machine will automatically remember the
breakpoint. When the power is switched on again, the breakpoint will be automatically found by the
machine. Press the "
RUN/PAUSE
" button to restart this step and continue to RUN the next step as
previous settings.
Temperature
Timing
Power