Ryobi RYi2322E Operation Manual - Page 16

Features

Page 16 highlights

FEATURES PRODUCT SPECIFICATIONS ENGINE Engine Type 79cc Overhead Valve (OHV) Spark Plug NGK BPR7HS or equivalent Lubricant Fill Volume approx. 12 oz Fuel Volume 1.2 gal. *Rated output determined by PGMA Standard G300 GENERATOR Rated Voltage 120V AC/5V DC Rated Amps 15A AC/2.1A DC Rated Output 1,800 W Starting Watts 2,300 W Rated Frequency 60 Hz KNOW YOUR GENERATOR See Figure 1. The safe use of this product requires an understanding of the information on the product and in this operator's manual as well as a knowledge of the project you are attempting. Before use of this product, familiarize yourself with all o­ perating features and safety rules. 120 V AC RECEPTACLES Your generator has two single phase, 60 Hz outlets that are 120 Volt AC, 20 Amp receptacles. These can be used for operating appropriate appliances, electrical lighting, tools, and motor loads. AIR FILTER The air filter helps to limit the amount of dirt and dust drawn into the unit during operation. AUTO-CHOKE This engine is equipped with battery free Auto-Choke system. AUTO IDLE BUTTON The auto idle button is used to control the speed of the engine and conserve fuel. When auto idle is on and no appliances are connected to the unit, the engine will idle. If an appliance is added, the engine speed will increase to power the item. If the appliance is removed, the engine will return to idle. AUTOMATIC SHUTOFF The generator's carbon monoxide sensor is designed to monitor the level of carbon monoxide present during generator operation. If the unit is positioned incorrectly and carbon monoxide levels rise to an unsafe level, the CO sensor LED will flash red and the generator will automatically shut down. Leave the area immediately and relocate to an open outdoor area. Ventilate the area thoroughly before occupying again. Ensure the generator is located in an open, outdoor area at least 20 feet away from all doors, windows, and occupied spaces, and point exhaust away from occupied structures before restarting. NOTE: After a shutoff event has occured, the LED will continue to flash red for up to 20 minutes. Once the generator is relocated and CO levels are safe, the generator can be restarted even if the light is still flashing. CARRY HANDLES This generator is equipped with a top carry handle for easy transport. The handle should be used to carry the generator. EASY START DIAL The EASY START dial is used when running and stopping the engine. It also controls the fuel valve. ELECTRIC START The electric start feature is powered by a RYOBI™ ONE+™ battery pack. NOTE: The generator engine does not charge or maintain the battery as it runs. NOTE: The GENCONTROL™ display must be on for the electric start function to work. If the display is off, verify the EASY START dial is in the ON position, then press and release the pairing button to wake the display from sleep mode. FUEL TANK The fuel tank has a capacity of 1.2 gallons. GENCONTROL™ WITH BLUETOOTH® WIRELESS TECHNOLOGY The GENCONTROL™ monitoring system with Bluetooth® wireless technology tracks fuel level, runtime, auto idle status and load. GROUND TERMINAL The ground terminal is used to assist in properly grounding the generator to help protect against electrical shock. Consult with a qualified local electrician for grounding requirements in your area. LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase is insufficient. OIL CAP/DIPSTICK Remove the oil fill cap to check and add lubricant to the generator when necessary. 12 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

12 — English
FEATURES
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all
operating
features and safety rules.
120 V AC RECEPTACLES
Your generator has two single phase, 60 Hz outlets that
are
120 Volt AC, 20 Amp receptacles. These can be used for
operating appropriate appliances, electrical lighting, tools,
and motor loads.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
AUTO-CHOKE
This engine is equipped with battery free Auto-Choke
system.
AUTO IDLE BUTTON
The auto idle button is used to control the speed of the
engine and conserve fuel. When auto idle is on and no ap-
pliances are connected to the unit, the engine will idle. If
an appliance is added, the engine speed will increase to
power the item. If the appliance is removed, the engine will
return to idle.
AUTOMATIC SHUTOFF
The generator’s carbon monoxide sensor is designed to
monitor the level of carbon monoxide present during genera-
tor operation. If the unit is positioned incorrectly and carbon
monoxide levels rise to an unsafe level, the CO sensor LED
will flash red and the generator will automatically shut down.
Leave the area immediately and relocate to an open outdoor
area. Ventilate the area thoroughly before occupying again.
Ensure the generator is located in an open, outdoor area at
least 20 feet away from all doors, windows, and occupied
spaces, and point exhaust away from occupied structures
before restarting.
NOTE:
After a shutoff event has occured, the LED will con-
tinue to flash red for up to 20 minutes. Once the generator
is relocated and CO levels are safe, the generator can be
restarted even if the light is still flashing.
CARRY HANDLES
This generator is equipped with a top carry handle for easy
transport. The handle should be used to carry the generator.
EASY START DIAL
The EASY START dial is used when running and stopping
the engine. It also controls the fuel valve.
ELECTRIC START
The electric start feature is powered by a RYOBI
ONE+
battery pack.
NOTE:
The generator engine does not charge or maintain
the battery as it runs.
NOTE:
The GENCONTROL
display must be on for the
electric start function to work. If the display is off, verify
the EASY START dial is in the ON position, then press and
release the pairing button to wake the display from sleep
mode.
FUEL TANK
The fuel tank has a capacity of 1.2 gallons.
GENCONTROL
WITH BLUETOOTH
®
WIRELESS TECHNOLOGY
The GENCONTROL
monitoring system with
Bluetooth
®
wireless technology tracks fuel level, runtime, auto idle
status and load.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Con-
sult with a qualified local electrician for grounding require-
ments in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
PRODUCT SPECIFICATIONS
ENGINE
Engine Type
.............................
79cc Overhead Valve (OHV)
Spark Plug
..............................
NGK BPR7HS or equivalent
Lubricant Fill Volume
.....................................
approx. 12 oz
Fuel Volume
.................................................................
1.2
gal.
GENERATOR
Rated Voltage
.............................................
120V AC/5V DC
Rated Amps
...............................................
15A AC/2.1A DC
Rated Output*
.........................................................
1,800 W
Starting Watts
.........................................................
2,300 W
Rated Frequency
........................................................
60 Hz
*Rated output determined by PGMA Standard G300